My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1999-2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
1301
>
2300 - Underground Storage Tank Program
>
PR0231342
>
COMPLIANCE INFO_1999-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/4/2021 3:26:07 PM
Creation date
6/3/2020 9:46:53 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1999-2009
RECORD_ID
PR0231342
PE
2361
FACILITY_ID
FA0000392
FACILITY_NAME
FLAMES LIQUOR
STREET_NUMBER
1301
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95242
APN
03104030
CURRENT_STATUS
01
SITE_LOCATION
1301 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231342_1301 W KETTLEMAN_1999-2009.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
391
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
.� "kc <br />Test Method Ry:manufactu rer O Industry Standard 0 Professional Engr, O Other'(see below) <br />Test Method; Uses: t� Pressure • Vacuum a Hydrostatic Q tither (see below) <br />Measuring Equipment Used:; Vacuum Gauge (rangeQ to SO inches Hgj <br />Descriation .::::,.-::::Tank #1 Tank #2 Tank #3 <br />Tank Manufacturer <br />Trusco <br />Trusco <br />Trusco <br />Tank TypeSteel <br />Steel <br />Steel <br />Tank Capacity <br />20,000 <br />10,000 <br />10,000 <br />Product Stored <br />Gasoline - 87 <br />Gasoline - 91 <br />Diesel <br />Is this a multi -compartment tank? <br />No <br />Yes <br />Yes <br />Brine filled or Dry Annular? <br />Dry <br />Dry <br />N/A <br />(if brine filled, perform no vacuum testing) <br />Monitoring system show normal annular? <br />Yes <br />Yes <br />N/A <br />Is water table above tank bottom? <br />Unknown <br />Unknown <br />N/A <br />Was sensor removed for testing? <br />N/A <br />Was sensor properly replaced after testing? <br />N/A <br />Wait time for vacuum to stabilize (hr:min) <br />0:20 <br />0:10 <br />Test start time <br />8:00 AM <br />8:01 AM <br />Initial vacuum (inches Hg) <br />7 <br />7 <br />Test end time <br />10:00 AM <br />10:01 AM <br />Final vacuum (inches Hg) <br />7 <br />7 <br />Test duration (hours:minutes) <br />2:00 <br />2:00 <br />Change in vacuum (inches Hg) <br />0 <br />0 <br />Pass/Fail threshold (inches Hg/hour) <br />2 <br />2 <br />TEST RESULT <br />PASS <br />PASS <br />Comments: <br />Tank #3 is the second compartment of a two compartment <br />tank <br />(#2 / #3). <br />No annular testing performed. <br />© 2002 Walton Engineering, Inc <br />
The URL can be used to link to this page
Your browser does not support the video tag.