My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
401
>
2300 - Underground Storage Tank Program
>
PR0231346
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/15/2023 4:05:16 PM
Creation date
6/3/2020 9:47:17 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231346
PE
2361
FACILITY_ID
FA0003603
FACILITY_NAME
TESORO (SPEEDWAY XP) 68152
STREET_NUMBER
401
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04513019
CURRENT_STATUS
01
SITE_LOCATION
401 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231346_401 W KETTLEMAN_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
620
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
L�] <br />QIMKMM�� <br />6. PIEPING SUMIP TESTING <br />L:1 <br />I est Metnod Developed By: 0 Sump Manufacturer 0 Industry Standard 0 Professional Engineer <br />0 Other (Specify) <br />Test Method Used: 0 Pressure 0 Vacuum R1 Hydrostatic <br />0 Other (Specify) <br />Test Equipment Used: Incon Sump Tester <br />Equipment Resolution: <br />Sump # 87 Sump # 91 <br />Sump # 91 <br />Sump # SL Sump # <br />Sunip # DSL Sump # <br />Sump Di eters 48" <br />Sump Depth: <br />6511 <br />Sump Material: <br />FIBERGLASS <br />Height from Tank Top to Top of <br />Hi ohest Piin :, Penetration - <br />30)) <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />13" <br />Condition of sump prior to testing: <br />CLEAN <br />Portion of Sump Tested' <br />HIGHEST <br />Does turbine shut down when <br />sump sensor detects liquid (both <br />roduct and water 9* <br />0 Yes 0 No 0 NA <br />0 Yes 0 No 0 NA <br />0 Yes El No 11 NA <br />0 Yes DNo (03]'NA <br />Turbine shutdown response time <br />SECONDS- <br />AUTO <br />AUTO <br />Is system programmed for fail-safe <br />— <br />shutdown?* <br />0 Yes 0 No 0 NA <br />0 Yes 0 No 0 NA <br />D Yes 0 No DNA <br />0 Yes 0 No 0 NA <br />Was fail-safe verified to be <br />o erational?* <br />0 Yes 0 No 0 NA <br />DYes 13NO DNA <br />0 Yes 0 No DNA <br />0 Yes 0 No D NA <br />Wait time between applying <br />pressure/vacuum/water and starting <br />15 IN <br />test: <br />Test Start Time: <br />9:32 A <br />Initial Reading (Rj)-, <br />3.3396 <br />Test End The: <br />9:47 AM <br />Final Reading (RF), <br />3.3383 <br />Test Duration: <br />15 MIN <br />Change in Reading (RF -R'): <br />.0013 <br />Pass/Fail TIreshold or Criteria: <br />.002 <br />Test Result:0, <br />0 Pass 0 Fail <br />Pass 0 Fail <br />IZ Pass 0 Fail <br />0 Pass 0 Fail <br />Was sensor removed for testing? <br />OYes DiZ [INA <br />OYes 0 N DNA <br />E3Yes DNo DNA <br />0 Yes 0 No 0 NA <br />Was sensor properly replaced and <br />verified functional after test-- <br />R01 0 <br />Y o 0 <br />Y�es[3 Noll NA <br />0 Yes 11 No 0 NA <br />comBrits — (include infarrrtation on repairs rrtade prior to testing, and recaended failaw-up far failed <br />tests) <br />If the entire depth of the sump is not tested, specify how much was tested. I f thp nnQ%xu-r tn <br />