EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
401
>
2300 - Underground Storage Tank Program
>
PR0231346
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/15/2023 4:05:16 PM
Creation date
6/3/2020 9:47:17 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231346
PE
2361
FACILITY_ID
FA0003603
FACILITY_NAME
TESORO (SPEEDWAY XP) 68152
STREET_NUMBER
401
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04513019
CURRENT_STATUS
01
SITE_LOCATION
401 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231346_401 W KETTLEMAN_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
620
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Veeder-Root Line Leak Applic9on Guide • <br />Check Valve Requirements <br />DPLLD, PLLD and WPLLD require certain check valves or Pressurstat assemblies to be installed on the pump. Use of noncom- <br />patible check valves can result in loss of leak detection performance. <br />NOTES: <br />1. The Veeder-Root High Pressure Check Valve (P/N 410153-002) is <br />shown below: <br />N <br />O <br />High pressure relief valve has <br />'H' stamped on underside of <br />poppet valve <br />2. For Red Jacket Quantum pumps, the SpikeCheck is the preferred check valve type. <br />3. 0.2/0.1 gph testing is supported for the Maxxum pump, but you must select 'User <br />Defined' as the pipe type during DPLLD or PLLD setup. <br />4. If maximum pump pressure is NOT a minimum of 5 psi below the pressurstat relief <br />setting, then a check valve must be installed in the discharge line of the slave pump (see <br />"Manifolded Line Applications" on page 11). <br />5. Veeder-Root does not warrant the performance of FE Petro's Model 'R' check valve or 65 <br />psi relief check valve. <br />6 <br />3.0 GPH ONLY <br />3.0, 0.2, 0.1 GPH <br />ADDITIONAL REWD. PARTS FOR MANI— <br />SUPPORTED <br />TESTING <br />TESTING <br />FOLDED LINES (SINGLE TANK W/2 STPS, <br />PUMPS <br />CHECK/RELIEF VALVE TYPE <br />(REWD. KIT) <br />(REWD. KIT) <br />OR 2 OR MORE TANKS w/ STP IN EACH) <br />DPLLD/PLLD <br />The Red Jacket <br />None Required <br />848480-001(TLS-350) <br />848480-001 (TLS -350) <br />Check Valve for Each Slave Pump P/N 410153-002 <br />859080-001 (TLS -450) <br />859080-001 (TLS -450) <br />(See illustration in Note 1 below) <br />Quantum (All Models) <br />Red Jacket SpikeCheck Valve (Factory <br />848480-001 (TLS -350) <br />848480-001 (TLS -350) <br />Red Jacket Quantum SpikeCheck Valve, Non -PSI <br />(See Note 2 below) <br />Installed) <br />859080-001(U-450) <br />859080-001 (TLS -450) <br />Relief Valve, Required for Each Slave Pump, P/N 388 - <br />081-5 (Field Installed Only) <br />Red Jacket SpikeCheck Valve (Field Only <br />848480-001 (TLS -350) <br />848480-001 (TLS -350) <br />Installed) P/N 388-080-5 <br />859080-001 (TLS -450) <br />859080-001 (TLS -450) <br />Red Jacket Pressurstat Assembly. <br />848480-001 (TLS -350) <br />— Not supported --- <br />Non -Vented SwiftCheck Valve for Each Slave Pump <br />859080-001(TLS-450) <br />kit, P/N 330020-416 <br />SwiftCheck <br />848480-003 (TLS -350) <br />848480-003 (TLS -350) <br />859080-002 (TLS -450) <br />859080-002 (TLS -450) <br />Standard (All Models) <br />SwiftCheck <br />848480-003 (TLS -350) <br />848480-003 (TLS -350) <br />Non -Vented SwiftCheck Valve for Each Slave Pump <br />859080-002 (TLS -450) <br />859080-002 (TLS -450) <br />kit, P/N 330020-416 <br />Red Jacket Functional Element Assembly <br />848480-001 (TLS -350) <br />--- Not supported -- <br />859080-001 (TLS -450) <br />Red Jacket SpikeCheck Valve (Field <br />848480-001 (TLS -350) <br />848480-001 (TLS -350) <br />Red Jacket Standard SpikeCheck Valve, Non -PSI <br />Installed Only) P/N 410557-001 <br />859080-001 (TLS -450) <br />859080-001 01S-450) <br />Relief Valve, Required for Each Slave Pump, P/N <br />410557-002 (Field Installed Only) <br />Maxxum <br />None Required <br />848480-001 (TLS -350) <br />859080-001 (TLS -450) <br />848480-001 (TLS -350) <br />859080-001 (TLS -450) <br />See Note 4 below. <br />Big -Flo <br />Pressurstat Kit P/N 144-314-5 <br />(See Note 3 below) <br />FE Petro <br />FE Petro Model R P/N 400988932 and <br />848480-001 (TLS -350) <br />848480-001 (TLS -350) <br />Non -Vented SwiftCheck Valve for Each Slave Pump <br />Replacement 0 -ring for the Valve Housing <br />859080-001 (TLS -450) <br />859080-001 (TLS -450) <br />kit, P/N 330020-416 ---- OR-- <br />(See Note 4 below) <br />FE Petro 65 psi Relief Check Valve (FE P/N <br />FE Petro Model R Relief Valve P/N <br />402459931) (See Note 5 below) <br />401330902 <br />Tokheim & Bennett <br />SwiftCheck <br />848480-003 (TLS -350) <br />848480-003 (TLS -350) <br />Non -Vented SwiftCheck Valve for Each Slave Pump <br />WPLLC1 Applications <br />859080-002 (TLS -050) <br />859080-002 (TLS -450) <br />kit, P/N 330020-416 <br />The Red Jacket <br />None Required <br />849490-006 <br />849490-006 <br />High Pressure Check Valve for Each Slave Pump, P/N <br />410153-002 (See illustration in Note 1 below) <br />Quantum (All Models) <br />Red Jacket SpikeCheck Valve (Factory <br />849490-005 <br />849490-005 <br />Non -Vented SwiftCheck Valve for Each Slave Pump <br />(See Note 2 below) <br />Installed) <br />(Except CPT) <br />(Except CPT) <br />kit, P/N 330020-416 <br />Red Jacket Pressurstat Assembly <br />849490-005 <br />— — Not supported -- <br />(Except CPT) <br />Standard (All Models) <br />SwiftCheck <br />849490-002 <br />849490-002 <br />(Except CPT) <br />(Except CPT) <br />Red Jacket Functional Element Assembly <br />849490-003 <br />------ Not supported — — <br />(Except CPT) <br />FE Petro <br />FE Petro Model R P/N 400988932 and <br />849490-001 <br />849490-001 <br />Non -Vented SwiftCheck Valve for Each Slave Pump <br />Replacement 0 -ring for the Valve Housing <br />kit, P/N 330020-416 --OR — <br />(See Note 5 below) <br />FE Petro 65 psi Relief Check Valve (FE P/N <br />402459931) (See Note 5 below) <br />NOTES: <br />1. The Veeder-Root High Pressure Check Valve (P/N 410153-002) is <br />shown below: <br />N <br />O <br />High pressure relief valve has <br />'H' stamped on underside of <br />poppet valve <br />2. For Red Jacket Quantum pumps, the SpikeCheck is the preferred check valve type. <br />3. 0.2/0.1 gph testing is supported for the Maxxum pump, but you must select 'User <br />Defined' as the pipe type during DPLLD or PLLD setup. <br />4. If maximum pump pressure is NOT a minimum of 5 psi below the pressurstat relief <br />setting, then a check valve must be installed in the discharge line of the slave pump (see <br />"Manifolded Line Applications" on page 11). <br />5. Veeder-Root does not warrant the performance of FE Petro's Model 'R' check valve or 65 <br />psi relief check valve. <br />6 <br />
The URL can be used to link to this page