My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
401
>
2300 - Underground Storage Tank Program
>
PR0231346
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/15/2023 4:05:16 PM
Creation date
6/3/2020 9:47:17 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231346
PE
2361
FACILITY_ID
FA0003603
FACILITY_NAME
TESORO (SPEEDWAY XP) 68152
STREET_NUMBER
401
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04513019
CURRENT_STATUS
01
SITE_LOCATION
401 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231346_401 W KETTLEMAN_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
620
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Veeder-Root Line Leak Applicoon Guide <br />TLS -450 Series Consoles Hardware Required for DPLLD Leak Detection <br />Digital Pressurized Line Leak Detector (DPLLD) - Order one per line. <br />MODEL <br />859080-001 PRESSURIZED LINE LEAK DETECTOR WITHOUT SWIFTCHECK VALVE <br />859080-002 PRESSURIZED LINE LEAK DETECTOR WITH SWIFTCHECK VALVE <br />Modules <br />• One Universal Sensor Module is required per console. One USM module monitors up to 16 lines. <br />• One Input/Output Module is required per console. One 1/0 module monitors up to 5 lines. <br />MODEL <br />332812-001 UNIVERSAL SENSOR MODULE <br />332813-001 INPUT/OUTPUT MODULE <br />TLS -350 Hardware Required for PLLD Leak Detection <br />Pressurized Line Leak Detector (PLLD) <br />Order one per line. <br />MODEL <br />848480-003 PRESSURIZED LINE LEAK DETECTOR WITH SWIFTCHECK VALVE <br />848480-001 PRESSURIZED LINE LEAK DETECTOR WITHOUT SWIFTCHECK VALVE <br />PLLD Modules <br />•TLS-350/TLS-350 PlusrrLS-350R Consoles - Leak Detection for up to 6 Lines <br />One Pressurized Line Leak Detector Interface Module is required per console. Order PLLD Controller modules as required <br />- one Controller module monitors up to 3 lines. <br />MODEL <br />330843-001 SIX INPUT PRESSURIZED LINE LEAK INTERFACE MODULE (MAXIMUM 1 PER CONSOLE) <br />330374-001 PRESSURIZED LINE LEAK CONTROLLER MODULE (MAXIMUM 2 PER CONSOLE) <br />•TLS -350J Consoles - Leak Detection for up to 4 Lines <br />One 'J' PLLD Interface Module is required per console. Order PLLD Controller modules as required - one Controller module <br />monitors up to 3 lines. <br />MODEL <br />330843-002 'J' PLLD INTERFACE MODULE (MAXIMUM 1 PER CONSOLE) <br />330374-001 PRESSURIZED LINE LEAK CONTROLLER MODULE (MAXIMUM 2 PER CONSOLE) <br />PLLD Precision Testing Software Module <br />Precision line leak detection capability (0.2 gph / 0.1 gph) requires one SEM (Software Enhancement Module) for the console <br />that must be ordered separately from the table below. Not required for 3.0 gph-only line leak detection capability. <br />ULTIMATE TESTING 330160-010 330160-110 <br />RISK MANAGEMENT 330160-060 330160-160 <br />BASE COMPLIANCE 330160-050 330160-150 <br />3.0 GPH INCLUDED' INCLUDED' <br />'A SEM is not required for 3 GPH-only testing. <br />7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.