Laserfiche WebLink
Jun-P-2002 03:17pm From-ARCO PROD +714-670-3095 T-919 P.0O5/OO6 F-953 <br /> k'. Yn.Tan4 Gauging/SM Equipment: ❑ heck this bo),if tank eauging is used only for inventory control. <br /> �I Check this bo). if no tank gauging or SIR equipment is installed. <br /> ° This section must be completed if in-tank gau;ing equipment is used to perforin leak detection monitorinal. <br /> Gam lets the follo, ng checklist: <br /> ❑ Yes 1 ❑ Nom Has all input wiring bcen inspected for proper envy and term,nation,including testing for ground faults? <br /> ❑ Yes ❑ No* Were all tank-gauging probes visually inspected for datnaa and residue buildup? <br /> ❑ Yes ❑ No* Was accuracy of system product level readings tested? <br /> ❑ Yes ❑ Now Was accuracy of system water level readings tested? <br /> ❑ Yes ® No* Were.all probes reinstalled properly? <br /> [Were all items on the equipment rrlanufacturer's maintenance checklist completed? <br /> Ir In the Section H,below,describe how and when these deficiencies were or will be corrected, <br /> G. Line lL,e;tk Detectors (LLD).- © Check this box if LLDs are not histalled. <br /> COMPIC the roll& inp checklist: <br /> Yes 0 No* For equipment start-up or annual equipment certification, was a leak simulated to verify LLE) perfomance? <br /> © NIA (Ct:ick all rhar app(y) Simulated leak race: M 3 g.p.h.; A 0.1 g.p.h; ©0.2 g.p.h. <br /> l� Yes 0 No* Were all LLDs confucrned operational and accurate within regalatory requirements? <br /> dpi Yes ❑ No's Was the testing apparatus properly calibrated? <br /> Yes ❑ No* For mechanical LLDs,does the LLD restrict product flow if ii detects a leak? <br /> ❑ N/A <br /> X Yes ❑ No* For electronic LLDs,does the turbine automatically shut off ii the LLD•detecm a leak? <br /> ❑ N/A <br /> Yes M Now For electronic LLDs,does the turbine auto=dcally shut off X any portion of the monitoring system is disabled <br /> ❑ N/A or disconnected? <br /> IX Yes ❑ No* For electronic LLDs,does the turbine automatically shut off ii any portion of the monitoring system malfunctions <br /> d N/A or fails a test? <br /> Yes ❑ No* For electronic LLDs,have aIi accessible wiring connections buen visually inspected? <br /> 0 N/A <br /> Yes ❑ No, Were all items on the equipment Manufacrurer's maintenance.:heckl4s completed? <br /> In the Section H,below,describe how and when these deficiencies were or will be corrected_ <br /> r <br /> H. Comments: ��1 ' eC ggp iC' <br /> let ,S <br /> Page 3 of 3 ttsroi <br />