My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
3425
>
2300 - Underground Storage Tank Program
>
PR0231416
>
COMPLIANCE INFO_2006-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/15/2024 4:11:28 PM
Creation date
6/3/2020 9:48:25 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2008
RECORD_ID
PR0231416
PE
2361
FACILITY_ID
FA0003627
FACILITY_NAME
ARCO 02093
STREET_NUMBER
3425
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
21418020
CURRENT_STATUS
01
SITE_LOCATION
3425 TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231416_3425 TRACY_2006-2008.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
366
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TEST NO. 1- FILL RISER CONT NT SUMP TESTING <br />Facility is Not Equipped With Fill Riser Containment Sumps ❑ <br />Fill Riser Containment Sumps are Present, but were Not Tested ❑ <br />Test Method Developed By: <br />❑ Sump Manufacturer <br />❑ Other (Spec) <br />® Industry Standard ❑ Professional Engineer <br />Test Method Used: <br />❑ Pressure <br />❑ Other (Spec) <br />❑ Vacuum <br />0 Hydrostatic <br />Test Equipment Used: Incon Tester <br />Equipment Resolution: <br />Fill Sump #87-1 <br />Fill Sump #87-2 <br />Fill Sump #87-3 <br />Fill Sump #91 <br />Sump Diameter: XXX <br />Sump Depth: XXX <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />Condition of sump prior to <br />testing: <br />Portion of Sump Tested <br />Sump Material: <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Fiber lass <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: Per Protocol <br />Test Start Time: <br />3:39pm <br />3:39pm <br />3:39pm <br />3:39pm <br />Initial Reading (RI): <br />1.5536 <br />3.4896 <br />2.6002 <br />2.5703 <br />Test End Time: <br />3:54pm <br />3:54pm <br />3:54pm <br />3:54pm <br />Final Reading F): <br />1.5547 <br />3.4891 <br />2.6003 <br />2.5717 <br />Test Duration: <br />15 min. <br />15 min. <br />15 min. <br />15 min. <br />Change in Reading (RF -RI): <br />+.0011 <br />-.0005 <br />+.0001 <br />+.0014 <br />Pass/Fail Threshold or Criteria: <br />3rdParty Certified <br />3 Id Party Certified <br />3' Party Certified <br />3rdParty Certified <br />Test Result: <br />' D Pass ❑Fail <br />®Pass' ❑ Fail <br />D Pass ❑ Fail <br />„. <br />ID -Pass: ❑ Fail <br />Is there a sensor in the sump? <br />❑ Yes ❑ No <br />❑ Yes ❑ No <br />❑ Yes ❑ No <br />® Yes ❑ No <br />Does the sensor alarm when <br />either product or water is <br />detected? <br />❑Yes ❑No DNA <br />❑Yes ❑No DNA <br />❑Yes ❑No DNA <br />❑Yes ❑No DNA <br />Was sensor removed for testing? <br />❑ Yes ❑No DNA <br />❑ Yes ❑ No DNA <br />❑Yes ❑ No ❑ NA <br />❑ Yes ❑ No DNA <br />Was sensor properly replaced and <br />verified functional after testing? <br />❑ Yes ❑No DNA <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No DNA <br />❑ Yes ❑ No DNA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />
The URL can be used to link to this page
Your browser does not support the video tag.