My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
3425
>
2300 - Underground Storage Tank Program
>
PR0231416
>
COMPLIANCE INFO_2006-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/15/2024 4:11:28 PM
Creation date
6/3/2020 9:48:25 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2008
RECORD_ID
PR0231416
PE
2361
FACILITY_ID
FA0003627
FACILITY_NAME
ARCO 02093
STREET_NUMBER
3425
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
21418020
CURRENT_STATUS
01
SITE_LOCATION
3425 TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231416_3425 TRACY_2006-2008.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
366
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TEST NO.2 - PIPING SUMP TESTING <br />Test Method Developed By: ❑ Sump Manufacturer 0 Industry Standard ❑ Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: ❑ Pressure ❑ Vacuum 0 Hydrostatic <br />❑ Other (Spec) <br />Test Equipment Used: Incon Tester <br />Equipment Resolution: <br />Sump #87-1 STP <br />Sump #87-2 STP <br />Sump #87-3 STP <br />Sump #91 STP <br />Sump Diameter: XXX <br />Sump Depth: XXX - <br />Sump Material: <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />Condition of sump prior to testing: <br />Portion of Sump Tested': <br />2" Above Piping <br />2" Above Piping <br />2" Above Piping <br />2" Above Piping <br />Does turbine shut down when <br />sump sensor detects liquid (both <br />product and water)?" <br />❑ Yes ❑No EINA <br />❑ Yes ❑No t]NA <br />❑ Yes ❑No ®NA <br />❑ Yes ❑No ONA <br />Turbine shutdown response time <br />Is system programmed for fail-safe <br />shutdown? <br />❑ yes ❑No ONA <br />❑ Yes ❑No ONA <br />❑ Yes ❑No EINA <br />❑ Yes ❑No ONA <br />Was fail-safe verified to be <br />operational?* <br />❑ yes ❑No ®NA <br />❑ Yes ❑No ONA <br />❑ Yes ❑No ®NA <br />❑ Yes ❑No EINA <br />Wait time between applying <br />pressure/vacuum/water and starting <br />test: Per Protocol <br />Test Start Time: <br />3:14pm <br />1:53pm <br />12:28pm <br />12:28pm <br />Initial Reading (RO: <br />4.7705 <br />3.9400 <br />2.8210 <br />4.2653 <br />Test End Time: <br />3:29pm <br />2:08pm <br />12:43pm <br />12:43pm <br />Final Reading (RF): <br />4.7705 <br />3.9407 <br />2.8223 <br />4.2670 <br />Test Duration: <br />15 min. <br />15 min. <br />15 min. <br />15 min. <br />Change in Reading (RF -RI): <br />none <br />+.0007 <br />+.0013 <br />+.0017 <br />Pass/Fail Threshold or Criteria: <br />3`d Party Certified <br />3rd Party Certified <br />3`d Party Certified <br />3rd Party Certified <br />Tesf Result: <br />® ;Pass '❑ Fail <br />El Pass ❑ Fail <br />0 Pass ❑ Fail <br />0 Pass 0 Fail <br />Was sensor removed for testing? <br />❑ Yes ❑No DNA <br />❑ Yes ❑ No DNA <br />❑ Yes ❑ No DNA <br />❑ Yes ❑ No ❑ NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />0 e ❑No DNA <br />❑ Yes ❑No ❑ NA <br />❑ Yes ❑ No DNA <br />❑Yes ❑ No ❑ NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />' If the entire depth of the sump is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />Ot <br />