TEST NO.2 - PIPING SUMP TESTING <br />Test Method Developed By: ❑ Sump Manufacturer 0 Industry Standard ❑ Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: ❑ Pressure ❑ Vacuum 0 Hydrostatic <br />❑ Other (Spec) <br />Test Equipment Used: Incon Tester <br />Equipment Resolution: <br />Sump #87-1 STP <br />Sump #87-2 STP <br />Sump #87-3 STP <br />Sump #91 STP <br />Sump Diameter: XXX <br />Sump Depth: XXX - <br />Sump Material: <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />Condition of sump prior to testing: <br />Portion of Sump Tested': <br />2" Above Piping <br />2" Above Piping <br />2" Above Piping <br />2" Above Piping <br />Does turbine shut down when <br />sump sensor detects liquid (both <br />product and water)?" <br />❑ Yes ❑No EINA <br />❑ Yes ❑No t]NA <br />❑ Yes ❑No ®NA <br />❑ Yes ❑No ONA <br />Turbine shutdown response time <br />Is system programmed for fail-safe <br />shutdown? <br />❑ yes ❑No ONA <br />❑ Yes ❑No ONA <br />❑ Yes ❑No EINA <br />❑ Yes ❑No ONA <br />Was fail-safe verified to be <br />operational?* <br />❑ yes ❑No ®NA <br />❑ Yes ❑No ONA <br />❑ Yes ❑No ®NA <br />❑ Yes ❑No EINA <br />Wait time between applying <br />pressure/vacuum/water and starting <br />test: Per Protocol <br />Test Start Time: <br />3:14pm <br />1:53pm <br />12:28pm <br />12:28pm <br />Initial Reading (RO: <br />4.7705 <br />3.9400 <br />2.8210 <br />4.2653 <br />Test End Time: <br />3:29pm <br />2:08pm <br />12:43pm <br />12:43pm <br />Final Reading (RF): <br />4.7705 <br />3.9407 <br />2.8223 <br />4.2670 <br />Test Duration: <br />15 min. <br />15 min. <br />15 min. <br />15 min. <br />Change in Reading (RF -RI): <br />none <br />+.0007 <br />+.0013 <br />+.0017 <br />Pass/Fail Threshold or Criteria: <br />3`d Party Certified <br />3rd Party Certified <br />3`d Party Certified <br />3rd Party Certified <br />Tesf Result: <br />® ;Pass '❑ Fail <br />El Pass ❑ Fail <br />0 Pass ❑ Fail <br />0 Pass 0 Fail <br />Was sensor removed for testing? <br />❑ Yes ❑No DNA <br />❑ Yes ❑ No DNA <br />❑ Yes ❑ No DNA <br />❑ Yes ❑ No ❑ NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />0 e ❑No DNA <br />❑ Yes ❑No ❑ NA <br />❑ Yes ❑ No DNA <br />❑Yes ❑ No ❑ NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />' If the entire depth of the sump is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />Ot <br />