My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
3425
>
2300 - Underground Storage Tank Program
>
PR0231416
>
COMPLIANCE INFO_2006-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/15/2024 4:11:28 PM
Creation date
6/3/2020 9:48:25 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2008
RECORD_ID
PR0231416
PE
2361
FACILITY_ID
FA0003627
FACILITY_NAME
ARCO 02093
STREET_NUMBER
3425
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
21418020
CURRENT_STATUS
01
SITE_LOCATION
3425 TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231416_3425 TRACY_2006-2008.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
366
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TEST NO.2 - UNDER -DISPENSER CONTAINMENT (UDQ TESTING Page 1 of 1 <br />Test Method Developed By: ❑ UDC Manufacturer O Industry Standard ❑ Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: ❑ Pressure ❑ Vacuum O Hydrostatic <br />❑ Other (Spec) <br />Test Equipment Used: Incon Tester <br />Equipment Resolution: <br />UDC #1&2 <br />UDC #3&4 <br />UDC #5&6 <br />UDC #7&8 <br />UDC Manufacturer: <br />Green Plastic <br />Green Plastic <br />Green Plastic <br />Green Plastic <br />UDC Material: <br />Plastic <br />Plastic <br />Plastic <br />Plastic <br />UDC Depth: XXX <br />Height from UDC Bottom to Top <br />of Highest Piping Penetration: <br />Height from UDC Bottom to <br />Lowest Electrical Penetration: <br />Condition of UDC prior to <br />testing: <br />Portion of UDC Tested <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />product and water)?* <br />❑ Yes ❑No MINA <br />❑ Yes ❑No ONA <br />❑ Yes ❑No ONA <br />❑ Yes ❑No ONA <br />Turbine shutdown response time <br />Is system programmed for fail- <br />safe shutdown?* <br />❑ Yes ❑ No ONA <br />❑ Yes ❑ No ONA <br />❑ Yes ❑ No ONA <br />❑ Yes ❑ No ONA <br />Was fail-safe verified to be <br />operational?* <br />❑ Yes ❑No ONA <br />❑ Yes ❑No ONA <br />❑ Yes ❑No ONA <br />❑ Yes ❑No ONA <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test <br />Test Start Time: <br />6:47pm <br />6:47pm <br />8:04pm <br />8:04pm <br />Initial Reading (RI): <br />2.2801 <br />3.7965 <br />7.4329 <br />6.6569 <br />Test End Time: <br />7:03pm <br />1:03pm <br />8:20pm <br />8:20pm <br />Final Reading (RF): <br />2.2797 <br />3.7972 <br />7.4319 <br />6.6566 <br />Test Duration: <br />16 min. <br />16 min. <br />16 min. <br />16 min. <br />Change in Reading F -RI): <br />-.0004 <br />+.0007 <br />-.0010 <br />-.0003 <br />—Party <br />Pass/Fail Threshold or Criteria: <br />_YTP—arty Certified <br />3r Party Certified <br />3rd Party Certified <br />3` Certified <br />TestResultF <br />0," Vass " GD Fail : <br />®=Pass "' Fait <br />®Pass ❑Fail <br />Pass D Fail,. <br />Was sensor removed for testing? <br />❑ Yes ❑No ONA <br />❑ Yes ❑ No ❑NA <br />❑Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />❑ Yes ❑No ONA <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />