Laserfiche WebLink
LG 113 Vendor/Template Page 3 of 3 <br /> a <br /> one other sensor mounted higher as a high-water cut-off. <br /> Both Models 510 and 516 Discriminating Sensors were not evaluated for the ability to detect a layer of hydrocart <br /> water. <br /> EOS100 has 5 sensing points that can sense fuel or water over a 3.5-inch range. The highest sensor(level 5) ac <br /> level switch. <br /> If water is detected at level 5, a fuel alarm will be triggered instead of a water alarm. <br /> If fuel is detected at any of the levels, a fuel alarm will be triggered. <br /> The output from the system can be used to shut down the turbines when fuel is present or when water reaches 1 <br /> level switch. <br /> Model 522 Remote Monitoring System: <br /> Evaluation indicates that when threshold level of Model 406 Liquid Level Sensor, Models EOS100, 510 and 516 Di <br /> Sensor was reached, Model 522 Remote Monitoring System produced (1)an audible and visual alarm and (2) an <br /> signal that was recognized by a Veeder-Root TLS-350 Monitoring System. <br /> The TLS-350 Monitoring System produced an alarm within 10 seconds, and displayed and printed a notice of alar <br /> alarm time. <br /> Manufacturer states that the output signal produced by Model 522 Remote Monitoring System can be recognized <br /> monitoring systems designed to detect this output signal. <br /> Model 522 Remote Monitoring System was evaluated only using the Veeder-Root TLS-350 Monitoring System. <br /> Model 522T Monitoring System: <br /> Evaluation indicates that when threshold level of Model 406 Liquid Level Sensor, Models EOS100, 510 and 516 Di <br /> Sensor was reached, Model 522T Monitoring System will generate a visual (LCD readout and LED"alarm"lamp) <br /> alarm and also open up to three normally closed relay contacts. <br /> By using a Model 5228 Relay, the system can use these normally closed relay contacts to control power to turbin <br /> Alternatively, the normally closed relay contacts can be used to send fuel alarm information to a Veeder-Root TL! <br /> both positive shutdown and additional alarm notification (such as a printout showing the date and time that a rel <br /> occurred). <br /> Beaudreau Electronics, Inc. Evaluator: Ken Wilcox Associates <br /> 23 Industrial Drive Tel: (816) 443-2494 <br /> Waterford, CT 06285-9715 Date of Evaluation: 07/20/94 <br /> Tel: (860) 443-6570 (Revised 03/02/01, 09/23/02, 12/23/02, <br /> E-mail: customerservice@beaudreauelectric.com 08/28/03, 12/01/03) <br /> URL: www.beaudreauelectric.com <br /> I Home I Vendors: A-F I Vendors: G -M I Vendors: N -S I Vendors: T-Z I Method Index ' <br /> Appearance on this list is not to be construed as an endorsement by any regulatory agency nor is it any guarantee of the performance of the <br /> method or equipment. <br /> Equipment should be installed and operated in accordance with all applicable laws and regulations. <br /> http://www.swrcb.ca.gov/cwphome/Ust/leak_prevention/lgl13/Vendor Files/beaudreau elect... 3/28/05 <br />