9. UNDER -DISPENSER CONTAINMENT (IJDC) TV.STTN(. <br />Test Method Developed By: <br />El UDC Manufacturer ® Industry Standard El Professional Engineer <br />❑ Other (Specify) <br />Test Method Used: <br />❑ Pressure <br />❑ Other (Spec) <br />❑ Vacuum <br />® Hydrostatic <br />Test Equipment Used: Incon Sump <br />Tester <br />Equipment Resolution: <br />+/- 0.002" <br />-�; <br />UDC # .. <br />UDC # -1-F, <br />UDC # <br />UDC Manufacturer: <br />is ix S <br />UDC Material <br />le I.Z3L'^t; Ss <br />UDC Depth: <br />a� <br />i <br />Height from UDC Bottom to Top <br />of Highest Piping Penetration: <br />Height from UDC Bottom to <br />Lowest Electrical Penetration: <br />/0 " <br />y" <br />Condition of UDC prior to <br />testing: <br />vv r., <br />G oaD <br />Portion of UDC Tested <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />product and water)? <br />❑ Yes ❑ No [ NA <br />❑ Yes ❑ No [NNA <br />❑ Yes ❑ No [ NA <br />❑ Yes ❑ No [XNA <br />Turbine shutdown response time <br />A <br />Is system programmed for fail- <br />safe shutdown?' <br />❑ Yes ❑ No �(NA <br />❑ Yes ❑ No [-t NA <br />❑ Yes ❑ No �JNA <br />❑ Yes ❑ No [(NA <br />Was fail-safe verified to be <br />operational?* <br />❑ Yes ❑ No �f NA <br />❑ Yes ❑ No YNA <br />❑ Yes ❑ No `4NA <br />❑ Yes ❑ No '�6NA <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test <br />30 minutes <br />30 minutes <br />30 minutes <br />30 minutes <br />Test Start Time: <br />Initial Reading (Rj): <br />i �v <br />��.3 Lotai <br />Jv.'7 1,"7- <br />7vZTest <br />TestEnd Time: <br />-7!43-A•-. <br />q!-32-4 <br />fj131 A,. <br />/wL.,Z-9� <br />Final Reading (RF): <br />I j • I Pi 141 <br />o.,37-0 <br />v.7l.(ors <br />S . W "'3 <br />Test Duration: <br />V Z V'-- A41u„„ <br />*,— <br />Change in Reading(RF-Ri): <br />-vv@�► <br />p 1 <br />ht7d/1 <br />, wn& <br />Pass/Fail Threshold or Criteria: <br />+/- 0.002" <br />+/- 0.002" <br />+/- 0.002" <br />+/-0.002" <br />Test Result: <br />_s D Fail <br />Yes ❑ No ❑ NA <br />.-11 Fait <br />Yes ❑ No ❑ NA <br />4 Pass U Fail <br />Yes ❑ No ❑ NA <br />l Pass D Fail <br />Was sensor removed for testing? <br />Yes ❑ No ❑ NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />Njyes [:]No E]NA <br />``ff <br />)Q Yes E] No El NA <br />Yes E] No E] NA <br />1 <br />V Yes El No El NA <br />11 <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />' If the entire depth of the UDC is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire UDC must be tested. (See SWRCB LG -160) <br />