Laserfiche WebLink
San Joaquin County <br />Environmental Health Department AMENDED <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.or4/ehd <br />Facility Name: Facility Address: Date: <br />TRACY SHELL* 3725 N TRACY BLVD, TRACY January 25, 2017 <br />322 <br />HSC 25281.6(a) <br />Unburied below grade emergency generator system failed to meet exemption status <br />❑ V <br />❑ R <br />❑ COS <br />323 <br />HSC 25283.5(a) <br />Unburied below grade UST system failed to meet exemption status <br />❑ V <br />❑ R <br />❑ COS <br />324 <br />CCR 2717.1(g) <br />Tampered with red tag <br />❑ V <br />❑ R <br />❑ COS <br />325 <br />CCR 2717.1(f) <br />Deposited petroleum into a red tagged UST <br />❑ V <br />❑ R <br />❑ COS <br />326 <br />HSC 25299(a)(9) <br />Tampered with or disabled leak detection devices or alarms <br />❑ V <br />❑ R <br />❑ COS <br />327 <br />CCR 2631.1 <br />UST system not compatible with the substance stored <br />❑ V <br />❑ R <br />❑ COS <br />328 <br />HSC 25298 <br />Failed to comply with temporary closure requirements <br />❑ V <br />❑ R <br />❑ COS <br />329 <br />HSC 25298 <br />Failed to comply with permanent closure requirements <br />❑ V <br />❑ R <br />❑ COS <br />330 <br />CCR 2636(f)(6) <br />Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system <br />❑ V <br />❑ R <br />❑ COS <br />401 1 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve ❑ V ❑ R ❑ COS <br />402 CCR 2643(d) Daily monitoring of suction pipe (pre -Jan 1984) not performed ❑ V ❑ R ❑ COS <br />403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed (pre -January 1984) ❑ V ❑ R ❑ COS <br />404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed (pre -January 1984) ❑ V ❑ R ❑ COS <br />2010 See below Unlisted Administration/Documentation violation ❑ V ❑ R ❑ COS <br />2030 See below Unlisted Operations/Maintenance violation ❑ V ❑ R ❑ COS <br />2060 See below Unlisted Design/Construction violation ❑ V ❑ R ❑ COS <br />,S4IMMARY OF ViTIDIV�° <br />'4:rrl er�eF==riacan.,r"6urlJnf?_untiru+r,c�r.runl,iti _ .. <br />Item # I Remarks <br />103 HSC 25292.2 Current financial responsibility documents not submitted. <br />Financial responsibility documents only cover three underground storage tanks at this facility. There are four <br />underground storage tanks at this facility. Please revise financial documents to include all four underground storage <br />tanks. Current financial responsibility documents are required to be submitted annually. Immediately log into the <br />California Environmental Reporting System (CERS) at http://cers.calepa.ca.gov/, and upload the required <br />documents. <br />This is a repeat violation, Class II. <br />105 CCR 2632(d)(1) Failed to have an approved UST monitoring plan. <br />The monitoring plan is not current and/or not approved by the EHD. Beneath Pipe Monitoring is Performed Using <br />the Following Method(s) enter "yes" for Leak Alarm Triggers Automatic Pump Shutdown, and "yes" for <br />Failure/Disconnect Triggers Pump Shutdown. Beneath Personnel Responsibilities, remove Mojgan Manvari from <br />Name of First Person Having Responsibility. The monitoring plan must be uploaded to the California Environmental <br />Reporting System (CERS). Immediately log into CERS, make the necessary changes, and submit for review by the <br />EHD. <br />This is a minor violation. <br />FA0003780 PR0231417 50001 01/25/201 / <br />EHD 23-01 Rev. 09/22/16 Page 3 of 6 Underground Storage Tank Program OIR <br />