My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
3725
>
2300 - Underground Storage Tank Program
>
PR0231417
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/12/2024 12:59:25 PM
Creation date
6/3/2020 9:48:49 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231417
PE
2361
FACILITY_ID
FA0003780
FACILITY_NAME
TRACY SHELL*
STREET_NUMBER
3725
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
21217030
CURRENT_STATUS
01
SITE_LOCATION
3725 N TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231417_3725 N TRACY_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
377
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A016 <br />• San Joaquin County <br />Environmental Health Department A��j®�� <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 AMENDED <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.or /q ehd I- ;t4 1 7 <br />Underground tarage-Tank Plrogramwnspectionepo <br />Facility Name: <br />Facility Address: <br />Date: <br />TRACY SHELL" <br />3725 N TRACY BLVD, TRACY <br />January 25, 2017 <br />ma <br />SUpNV <br />(CLASS,1, CLASS II, or Nl1IVOR - Nottceto Comply - a <br />r <br />Item # <br />Remarks <br />106 <br />CCR 2632(d)(2) Failed to have an approved UST response plan. <br />The response plan is not current and/or not approved by the EHD. Enter current responsible person in section four <br />and remove Monjgan Manvari as she is no longer the area manager for this facility. The response plan must be <br />uploaded to the California Environmental Reporting System (CERS). Immediately log into CERS, upload the <br />completed form, and submit for review by the EHD. Ensure a copy is available for inspection at any time. <br />This is a minor violation. <br />107 <br />CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br />An accurate UST Monitoring Site Plan was not submitted. Missing are the following: the sensor in the 89 product <br />submersible turbine pump (STP) sump, add the electronic line leak detectors to all four STP sumps, and sensors to <br />the diesel and 91 product fill sumps. A site plan must be submitted identifying the locations where monitoring will be <br />performed. Immediately log into the California Environmental Reporting System (CERS) at <br />http://cers.calepa.ca.gov/ and upload a copy of the UST Monitoring Site Plan. <br />This is a minor violation. <br />121 <br />CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report. <br />An inspection was last done on 1/27/2016 and an inspection report was issued identifying information to be <br />submitted to bring this site into compliance. This information was required to be submitted by 2/26/2016. This <br />information has not been received resulting in a non-compliant status for this facility. An operator that receives an <br />inspection report shall have 30 days to submit a written response that includes a statement documenting corrective <br />actions taken or proposing corrective actions which will be taken. Ensure that a written response documenting <br />corrective actions taken or proposed is submitted within 30 days of receiving an inspection report. The outstanding <br />violations include: violation 201, Failed to maintain alarm logs and/or records of follow up actions, violation 314, <br />primary containment is not tight. <br />This is a Class II violation. <br />201 <br />CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions. <br />The facility failed to document the L11: 91 fill sump fuel alarm on 4/9/2016; the L2 plus sump STP fuel alarm on <br />6/29/2016; and the L12 diesel fill sump piping sump fuel alarm on 10/11/2016. Monitoring records include: (1) date <br />and time of all monitoring or sampling; (2) monitoring equipment calibration and maintenance records; (3) results of <br />any visual observations; (4) results of sample analysis performed a lab or in the field; (5) logs of all readings of <br />gauges or other monitoring equipment, ground water elevations, or other test results; (6) results of inventory <br />readings and reconciliations. Document all fuel alarms going forth. <br />This is a repeat violation, Class II. <br />FA0003780 PR0231417 SCO01 01/25/2017 <br />EHD 23-01 Rev. 09/22/16 Page 4 of 6 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.