My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
3725
>
2300 - Underground Storage Tank Program
>
PR0231417
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/12/2024 12:59:25 PM
Creation date
6/3/2020 9:48:49 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231417
PE
2361
FACILITY_ID
FA0003780
FACILITY_NAME
TRACY SHELL*
STREET_NUMBER
3725
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
21217030
CURRENT_STATUS
01
SITE_LOCATION
3725 N TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231417_3725 N TRACY_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
377
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1�1 <br />8. U1NIMM-016FLINb K UU1N 1'AINAILINT (UUL) T"111NU <br />Test Method Developed By: ❑ UDC Manufacturer ® Industry Standard ❑ Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: ❑ Pressure ❑ Vacuum ® Hydrostatic <br />❑ Other (Spec) <br />Test Equipment Used: Incon Sump Tester Equipment Resolution: +/- 0.002" <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test <br />UDC #9/10 UDC #11/12 <br />UDC #13/14 <br />UDC # 15/16 <br />OPW OPW <br />OPW <br />OPW <br />UDC Manufacturer: <br />UDC Material: <br />Fiberglass Fiberglass <br />Fiberglass <br />Fiberglass <br />UDC Depth: <br />31" 31" <br />31" <br />31" <br />Height from UDC Bottom to Top <br />1.8604 3.6869 <br />1.8421 <br />3.7879 <br />of Highest Piping Penetration: <br />13" 13" <br />13" <br />13" <br />Height from UDC Bottom to <br />0.0003 0.0001 <br />0.0005 <br />0.0001 <br />Lowest Electrical Penetration: <br />61, 6" <br />6" <br />6" <br />Condition of UDC prior to <br />D Pass ❑ Fail ® Pass ❑ Fail <br />El Pass ❑ Fail <br />O Pass ❑ Fail <br />testing: <br />Good Good <br />Good <br />Good <br />Portion of UDC Tested <br />2" above piping 2" above piping <br />2" above piping <br />2" above piping <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />❑ Yes ElNo ® NA ElYes ❑ No ®NA <br />F-1Yes ❑ No ®NA <br />❑ Yes ❑ No ®NA <br />product and water)?* <br />Turbine shutdown response time <br />NIA N/A <br />N/A <br />N/A <br />Is system programmed for fail- <br />° <br />safe shutdown? <br />❑ Yes El No ® NA [:1 Yes ❑ No ®NA <br />❑ Yes ❑ No ®NA <br />El Yes ❑ No ®NA <br />Was fail-safe verified to be <br />s <br />Al1PY7I'tAN7�% <br />❑ Yes ❑ No ® NA ❑ Yes ❑ No ®NA <br />❑ Yes ❑ No ®NA <br />❑ Yes ❑ No ®NA <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test <br />30 minutes 30 minutes <br />30 minutes <br />30 minutes <br />Test Start Time: <br />1:31 pin 2:47 pm <br />2:17 prn <br />2:47 pin <br />Initial Readin (Rt): <br />1.8607 3.6868 <br />1.8416 <br />3.7878 <br />Test End Time: <br />1:46 pro 3:02 pm <br />2:32 pro <br />3:02 pin <br />Final Reading (RF): <br />1.8604 3.6869 <br />1.8421 <br />3.7879 <br />Test Duration: <br />15 min. 15 min. <br />15 min. <br />15 min. <br />Change in Reading (RF -RI): <br />0.0003 0.0001 <br />0.0005 <br />0.0001 <br />Pass/Fail Threshold or Criteria: <br />+/- 0.002" +/- 0.002" <br />+/- 0.002" <br />+1-0.00211 <br />Test Result: <br />D Pass ❑ Fail ® Pass ❑ Fail <br />El Pass ❑ Fail <br />O Pass ❑ Fail <br />Was sensor removed for testin ? <br />® Yes ❑ No ❑ NA ® Yes ❑ No ❑ NA <br />® Yes ❑ No DNA <br />® Yes ❑ No [INA <br />Was sensor properly replaced and <br />verified functional after testing? <br />® Yes ElNo ElNA ® Yes ❑ No ElNA <br />® Yes ElNo DNA <br />® Yes ❑ No [INA <br />Comments — (include information on repairs made prior to testing and recommended follow-up for failed tests) <br />"Sensor functionality was not confirmed. This procedure is not part of the Secondary Containment testing scope of work". <br />' If the entire depth of the UDC is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire UDC must be tested. (See SWRCB LG -160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.