n <br />11 <br />Test Method Developed By: ❑ UDC Manufacturer R Industry Standard ❑ Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: ❑ Pressure ❑ Vacuum ® Hydrostatic <br />❑ Other (Spec) <br />Test Equipment Used: Incon Sump <br />Tester Equipment Resolution: +/- 0.002" <br />UDC #1/2 <br />UDC #3/4 <br />UDC #5/6 <br />UDC # 7/8 <br />UDC Manufacturer: <br />OPW <br />OPW <br />OPW <br />OPW <br />UDC Material: <br />Plastic <br />Plastic <br />Plastic <br />Plastic <br />UDC Depth: <br />31" <br />31" <br />31" <br />31" <br />Height from UDC Bottom to Top <br />of Highest Piping Penetration: <br />14" <br />14" <br />14" <br />14" <br />Height from UDC Bottom to <br />Lowest Electrical Penetration: <br />14" <br />14" <br />14" <br />14" <br />Condition of UDC prior to <br />testing: <br />Good <br />Good <br />Good <br />Good <br />Portion of UDC Tested <br />2" above piping <br />2" above piping <br />2" above piping <br />2" above pi in <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />product and water)?* <br />❑ Yes ❑ No RNA <br />❑ Yes ❑ No RNA <br />❑ Yes ❑ No RNA <br />❑ Yes ❑ No RNA <br />Turbine shutdown response time <br />N/A <br />N/A <br />N/A <br />N/A <br />Is system programmed for fail- <br />safe shutdown? <br />❑ Yes ❑ No R NA <br />❑ Yes ❑ No RNA <br />❑ Yes ❑ No RNA <br />❑ Yes ❑ No RNA <br />Was fail-safe verified to be <br />o erational?` <br />❑ Yes ❑ No R NA <br />❑ Yes ❑ No RNA <br />❑ Yes ❑ No RNA <br />❑ Yes ❑ No ®NA <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test <br />30 minutes <br />30 minutes <br />30 minutes <br />30 minutes <br />Test Start Time: <br />1:37 pm <br />3:12 pm <br />2:14 pm <br />1:37 pm <br />Initial Reading (Rj): <br />3.3828 <br />2.6406 <br />5.2355 <br />4.2215 <br />Test End Time: <br />1:52 pm <br />3:27 pro <br />2:29 pm <br />1:52 prn <br />Final Reading (RF): <br />3.3830 <br />2.6403 <br />5.2350 <br />4.2216, <br />Test Duration: <br />15 min. <br />15 min. <br />15 min. <br />15 min. <br />Change in Reading (RF -Rt): <br />0.0002 <br />0.0003 <br />0.0005 <br />0.0001 <br />Pass/Fa*1 Threshold or Criteria: <br />+/-0.00211 <br />+/-0.00211 <br />+/-0.00211 <br />+/-0.00211 <br />Test Result: <br />0 Pass 0 Fail <br />0 Pass ❑ Fail <br />0 Pass 0 Fail <br />El Pass ❑ Fail <br />Was sensor removed for testing? <br />R Yes ❑ No ❑ NA <br />R Yes ❑ No ❑ NA <br />R Yes ❑ No [INA <br />R Yes ❑ No [INA <br />Was sensor properly replaced and <br />verified functional after testing? <br />R Yes ❑ No ❑ NA <br />R Yes ❑ No ❑ NA <br />R Yes ❑ No ❑NA <br />R Yes ❑ No [INA <br />Comments — (include information on repairs made prior to testing and recommendedfollow-up for failed tests) <br />"Sensor functionality was not confirmed. This procedure is not part of the Secondary Containment testing scope of work". <br />Replaced Test Boot in Disp #3/4. <br />If the entire depth of the UDC is not tested, specify how much was tested. If the answer to gpy of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire UDC must be tested. (See SWRCB LG -160) <br />