Laserfiche WebLink
ENVIRONMENTAL HEALTH DEPARTMENT <br />SAN JOAQUIN COUNTY <br />1868 E. Hazelton, Stockton, CA 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 <br />UNDERGROUND STORAGE TANK <br />RETROFIT VERIFICATION WITH INSPECTOR ALREADY ONSITE* <br />Facility Information <br />Facility Trac Shell <br />Name: y <br />Facility 3:725 N. Trac Blvd., Trac <br />Address: y y <br />Facility <br />Contact: MO1an Anvari <br />Title: Operator <br />Indicate below type of work to be performed. Check all that apply. <br />® Sensor replacement <br />Model: Veeder Root 794380-208 <br />❑ 87 piping sump <br />❑ 87 fill sump <br />Contractor Information <br />❑ 89 fill sump <br />Contractor <br />Name: <br />Service Station Systems <br />yems <br />❑ diesel piping sump <br />Contractor <br />Address: <br />680 Quinn Ave., San Jose, CA 95112 <br />CA License <br />Number: <br />485184 <br />Class: <br />C-61 ( D-40) <br />Contractor <br />Phone #: <br />408 213-6038 <br />() <br />Insurer: <br />ICW Groupworkers' <br />Comp. #: <br />WPL502130700 <br />ICC Tech: <br />Steve Parmenter <br />❑ other: <br />Exp. Date: <br />Apr 15, 2013 <br />ICC Installer: <br />❑ 87 -octane UST <br />Exp. Date: <br />❑ 91 -octane UST <br />Manufacturer Veede <br />Training:r Root <br />❑ other: <br />Exp. Date: <br />Mar 1, 2014 <br />Indicate below type of work to be performed. Check all that apply. <br />® Sensor replacement <br />Model: Veeder Root 794380-208 <br />❑ 87 piping sump <br />❑ 87 fill sump <br />❑ 89 piping sump <br />❑ 89 fill sump <br />x91 piping sump <br />❑ 91 fill sump <br />❑ diesel piping sump <br />❑ diesel fill sump <br />❑ dispenser 1/2 <br />❑ dispenser 3/4 <br />❑ dispenser 5/6 <br />❑ dispenser 7/8 <br />❑ other: Serial #972967 <br />❑ Leak detector replacement <br />Model: <br />❑ 87 -octane UST ❑ 89 -octane UST <br />❑ 91 -octane UST ❑ diesel UST <br />❑ other: <br />❑ Spill container replacement (not direct bury) <br />Model: <br />❑ 87 -octane UST ❑ 89 -octane UST <br />❑ 91 -octane UST ❑ diesel UST <br />❑ other: <br />❑ Bravo float and chain replacement <br />Dispenser: <br />Grade: _ <br />Dispenser: <br />Grade: _ <br />Dispenser: <br />Grade: _ <br />Dispenser: <br />Grade: _ <br />*This applies only if contractor has all required certifications. <br />❑ Sensor replacement <br />Model: <br />❑ 87 piping sump <br />❑ 87 fill sump <br />❑ 89 piping sump <br />❑ 89 fill sump <br />❑ 91 piping sump <br />❑ 91 fill sump <br />❑ diesel piping sump <br />❑ diesel fill sump <br />❑ dispenser 1/2 <br />❑ dispenser 3/4 <br />❑ dispenser 5/6 <br />❑ dispenser 7/8 <br />❑ other: <br />❑ Leak detector replacement <br />Model: <br />❑ 87 -octane UST <br />❑ 89 -octane UST <br />❑ 91 -octane UST <br />❑ diesel UST <br />❑ other: <br />❑ Spill container replacement (not direct bury) <br />Model: <br />❑ 87 -octane UST <br />❑ 89 -octane UST <br />❑ 91 -octane UST <br />❑ diesel UST <br />❑ other: <br />❑ Automatic tank gauge (ATG) replacement <br />Model: <br />❑ 87 -octane UST <br />❑ 89 -octane UST <br />❑ 91 -octane UST <br />❑ diesel UST <br />❑ other: <br />PR#: 02314171 PE: 2361 SC: 098 I Accepted To/ Stacy Rivera I Date: Jan 29, 2013 <br />