Laserfiche WebLink
Ll <br />0 <br />SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br />Fad <br />Name: Tracy Shell <br />Facility <br />Address: 3725 N. Tracy Blvd., Tracy <br /># <br />Inspection <br />Date: Jan 29, 2013 <br />Facility <br />Contact: Mojgan Anvari <br />M <br />Code Section <br />Title: <br />Operator <br />C1 = Class 1 violation; C2 = Class 2 violation; M = Minor violation <br />C) 932-6922 <br />Inspection <br />Type: X Routine X Monitoring System <br />Certification D Installation D Complaint - IDfk <br />D Other: <br />(Authority HSC 25289) <br />Consentfor. XInspection XSampling XPhotos <br />Grantedby:Tanya Moore <br />Title: Store Manager <br />Monitoring Veeder-Root TLS-35OR <br />Panel: <br />Piping <br />System: <br />X Pressurized C. Suction ❑ Gravit y <br />rfill <br />Prevention: <br />Pre <br />Mechanical ❑ Audible/visual <br />UST <br />---Product — <br />8 <br />9 <br />10 <br />CCR 2711 <br />11 <br />106 <br />x CCR 2632(b) <br />Monitoring Program (Monitoring & Response Plans) is not current or approved by the EHD <br />107 <br />CCR 2632(d)(1)(C) <br />Plot plantsite map not submitted or fails to completely show where monitoring is performed <br />108 <br />- 87 -octane -- <br />- 89 -octane -- <br />- 91 -octane - <br />-----DSL ---- <br />-------------- <br />-------------- <br />-------------- <br />Annual line leak detector test not performed (M1) <br />------------- <br />-------------- <br />ora�: Ryan Casey <br />Dae <br />9/15/12 <br />Violations: x M1 -Release Detection <br />i j M2 -Release Prevention : I M3 - Both <br />On Site Service Steve Parmenter <br />ICC Exp. <br />Manufacturer's <br />4/15/13 VR x. 3/1/14 <br />VMI x. 7/11/13 <br />Technician: <br />Date: <br />Training: <br />Repair for tank or piping not tested for tightness after completion of the repair pursuant to (M2) <br />permit conditions <br />Inspector. received By: Title: <br />Stacy Rivera (209) 468-3440 <br />VIOLATIONS <br /># <br />C1 <br />C2 <br />M <br />Code Section <br />HSC = California Health and Safety Code; CCR = California Code of Regulations <br />C1 = Class 1 violation; C2 = Class 2 violation; M = Minor violation <br />File Review <br />101 <br />HSC 25284 <br />No permit to operate <br />102 <br />HSC 25404.5 <br />Annual operating fees not paid <br />103 <br />HSC 25284(a)(3) <br />No written agreement between the person that the operating permit was issued to and the tank operator to <br />monitor the tanks stem <br />104 <br />HSC 25292.2 <br />Current financial responsibility documents not on file with the Environmental Health Department (EHD) <br />105 <br />CCR 2711 <br />Current Unified Program Consolidated Forms not on file with the EHD (Facility and tank form) <br />106 <br />x CCR 2632(b) <br />Monitoring Program (Monitoring & Response Plans) is not current or approved by the EHD <br />107 <br />CCR 2632(d)(1)(C) <br />Plot plantsite map not submitted or fails to completely show where monitoring is performed <br />108 <br />CCR 2637 <br />Secondary containment: (a) test not performed; (e) test report not submitted within 30 days; (f) test notification <br />not provided to the EHD at least 48 hours prior to conducting the test <br />109 <br />CCR 2638 <br />Monitoring equipment certification: (a) not performed annually; (d) test report not submitted within 30 days; <br />(e) test notification not provided to the EHD at least 48 hours prior to conducting an installation, repair, <br />replacement, calibration, or certification <br />110 <br />HSC 25291(f) <br />Annual line leak detector test not performed (M1) <br />111 <br />HSC 25284.2 <br />Annual spill containment testing not performed <br />112 <br />CCR 2636(f)(4) <br />Annual line tightness test not performed if positive shutdown or fail safe not present (M1) <br />113 <br />CCR 2715(a) <br />Failed to inform the EHD of a change of designated operator within 30 days <br />114 <br />CCR 2715(b) <br />Designated operator does not possess a current ICC CA UST System Operator certification <br />115 <br />CCR 2660(k) <br />Repair for tank or piping not tested for tightness after completion of the repair pursuant to (M2) <br />permit conditions <br />116 <br />HSC 25292.5 <br />Enhanced leak detection (ELD) testing not performed on a system located within 1 000'of public well, or <br />failures not repaired and retested <br />117 <br />CCR 2661 <br />Permit to repair UST system not obtained <br />118 <br />HSC 25286(a) <br />Operational permit not amended when UST storage and/or monitoring system changed <br />119 <br />HSC 25298(b) <br />Permit to temporarily close UST system not obtained <br />120 <br />HSC 25298(c) <br />Permit to dose UST system not obtained <br />On Site Records <br />201 <br />CCR 2712(b) <br />Maintenance & monitoring records not maintained 3 years, cathodic protection records for 6 % years, written <br />performance claims pertaining to release detection systems for 5 years, or records of repairs, linings, and <br />upgrades for the life of the tank. Monitoring records indude: (1) date and time of all monitoring or sampling; <br />(2) monitoring equipment calibration and maintenance records; (3) results of any visual observations; (4) <br />results of sample analysis performed a lab or in the field; (5) logs of all readings of gauges or other monitoring <br />equipment, round water elevations, or other test results; 6 results of inventory readings and reconciliations <br />202 <br />CCR 2712(1) <br />Monitoring plan, response plan, and/or operating permit and all conditions not onsite <br />203 <br />CCR 2650 <br />Unauthorized release that: (c) did not escape secondary containment and cleaned up within eight hours (M1) <br />was not recorded; (e) escaped secondary containment, not cleaned up after eight hours, or a sudden loss of <br />product was not reported to the EHD within 24 hours <br />Inspector. received By: Title: <br />Stacy Rivera (209) 468-3440 <br />