My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1997-1999
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
2072
>
2300 - Underground Storage Tank Program
>
PR0231426
>
COMPLIANCE INFO_1997-1999
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/10/2020 1:02:01 AM
Creation date
6/3/2020 9:48:53 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1997-1999
RECORD_ID
PR0231426
PE
2361
FACILITY_ID
FA0004625
FACILITY_NAME
YOSEMITE PETROLEUM
STREET_NUMBER
2072
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95337
APN
22202001
CURRENT_STATUS
01
SITE_LOCATION
2072 W YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231426_2072 W YOSEMITE_1997-1999.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
381
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONTHLY <br /> STATISTICAL I&ENTORY RECONCILIAT& (SIR) REPORT <br /> �.. ... <br /> Shields Ha elm Co. Oakland CA Phone: (800)772-2300 <br /> >SIR` ars& rx<>« SIR 5.7-Version 5.7.L.M Date of SIR Report: 5/15/98 <br /> �enod. oveired 4/98 What is the required number of usable inventory days per tank? 30 <br /> acUit':`Name€ < Franks One Stop Cust Site ID: FranksOn Simmons Site ID: MAHVAAA <br /> > afk LcacatjioR' Address: 2072 W.Yosemite Avenue Phone: (209)239-9575 <br /> 337 <br /> `> Ci Manteca <br /> State CA Zi : 95 Fax: <br /> city <br /> P <br /> >' `fiarKf) ner<< Name: Frank's One Stop Food Marts <br /> Yosemite Avenue <br /> Phone: 209 239-9575 <br /> > `: Address: 2072 <br /> W. Yo ( ) <br /> >' Cit : Manteca <br /> State: CA ZP <br /> i :95337 Fax: <br /> Y <br /> 11K:. Name: Frank'sOne Stop rood Maris <br /> StftunsCustamet< Talnk Tenk This Month Last Two <br /> Tank........ lank;? <br /> attents Capacity Month Months <br /> . N.umber Gallons): Ago <br /> LeakPass Fail <br /> Pass Fad, <br /> mum Calculated <br /> Pas Fal, <br /> Threshold Detectable Leak <br /> Incon- <br /> Incor- <br /> ircor- <br /> dusive <br /> usive <br /> d <br /> dusiv <br /> Leak Rate 6b <br /> e <br /> Rate 6c <br /> 98 eb 98 <br /> (Aix 981 (Mar 96 <br /> (F ) <br /> 9P 9P <br /> h <br /> 9 <br /> h h P F I P F 1 P F I <br /> P <br /> MAHVAAAI FOS1 Unleaded Plus 10,033 0.10 0.14 -0.08 * <br /> MAHVAAA2 FOS2 REGULAR UNLEADI 10,033 0.10 0.13 -0.06 <br /> MAHVAAA3 FOS4 Premium Unleaded 10,033 0.10 0.17 -0.09 <br /> MAHVAAA4 FOSS DIESEL 10,033 0.10 , 0,12 -0.08 <br /> N <br /> NOTE: N indicates No Analysis Performed Negative Calculated Leak Rates Indicate Gain <br /> G indicates Gaining trend <br /> 1.The tank owner is required to have a SIR report for each month. <br /> 2.Monthly repots mud be submitted to the local agency upon request. <br /> 3.The tank owner is required to have the report by the 20th day of the fdkrning month. <br /> 4.If for any reason,the ted is neither'pass'nor*W,the inconclusive column will be marked. <br /> 5.The kcal agency may need to be notified of the lank that does not pass the SIR ted within 24 tours of receipt o(the report and the SIR report should be <br /> submitted to the local agency within 10 days of the report. <br /> 6.Quantitative and Qualitative Methods: <br /> a.A leak threshold,minimum detectable leak rate,and calculated leak rate mud be provided for each tank.If not,then the tank failed the SIR ted. <br /> b.If the absokds value of the calculated Irak rate for the tank Is greater than or equal to the leak threshold and the minimum detectable leak rate Is ' <br /> Ion than the certified performance standard.OR the absolute value of the calculated leak rate is greater than or equal to the minrhwm detectable <br /> leak rate and the minimum detectable leek rate Is greater than the certified performance standard,the tank failed the SIR ted. <br /> c.if the minimum detectable leak rate for the twhk is greater than the certified penformaroe standard Q.s.,0.1 or 0.2 gph)and the absolute value of the <br /> calculated leak rate is fess than the minimim detectable leak rate,the test is Inconclusive for that month. <br /> d.Two consecutive failures and/or inconcknsives may require a tank and/or piping integrity test within 15 days from the date of the second report. <br /> The local agency should be contacted. <br /> 7.A conclusive resull of'pass'or fair is required to meet monthly leak detection requirements. <br /> Persah ctantucting;:evalua#lan Simmons Technician <br /> Ear Information Call Jim Cartmill Date of SIR Report: 5/15/98 <br />
The URL can be used to link to this page