My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1997-1999
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
2072
>
2300 - Underground Storage Tank Program
>
PR0231426
>
COMPLIANCE INFO_1997-1999
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/10/2020 1:02:01 AM
Creation date
6/3/2020 9:48:53 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1997-1999
RECORD_ID
PR0231426
PE
2361
FACILITY_ID
FA0004625
FACILITY_NAME
YOSEMITE PETROLEUM
STREET_NUMBER
2072
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95337
APN
22202001
CURRENT_STATUS
01
SITE_LOCATION
2072 W YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231426_2072 W YOSEMITE_1997-1999.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
381
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
All' MONTHLY <br /> STATISTICAL 19VENTORY RECONCILIATItN (SIR) REPORT <br /> ........... <br /> IR Provider Shields Harper& Co. Oakland CA Phone: (800)772-2300 <br /> SIR 1lerston SIR 5.7-Version 5.7.L.M Date of SIR Report: 4/27/98 <br /> Penod Covered : 3/98 What is the required number of usable inventory days per tank? 30 <br /> Faciltt Namt3 Franks One Stop Cust Site ID: FranksOn Simmons Site ID: MAHVAAA <br /> Tank Cocatien Address: 2072 W. Yosemite Avenue Phone: (209)239-9575 <br /> <> <br /> Sta a. <br /> CACity Manteca Zip: 95337 Fax: <br /> fiank:Owner;,;i,:;.;; Name: Frank's One Stop Food Marts <br /> -9575Aoldness: 2072 W.-Yosemite Avenue Phone: l209) <br /> 239 <br /> t • C Zi :95337 Fax: <br /> CRY: Manteca <br /> IS <br /> tat <br /> e. A <br /> Y <br /> Tank operator ., Name: Frank's One Stop Food Marts <br /> Slmmtana. uetomer Tank Tank . ! This Month Last Two <br /> Tann Tank Contents Capaaty Month Months <br /> :Number Number (gallons Ago <br /> '>:><::::. : <br /> Leak Minimum Calculated Pass Fail, Pass Fail, Pass,Fail, <br /> rn <br /> reshoid Detectable Leak Rat Incon- ancon- Inuan- <br /> eak ( ) dusave dusrve dusrve <br /> L e lib <br /> Rate <br /> (tartar 98) (Feb 98) (Jan 98) <br /> 9ph gph gph P F I P F I P F <br /> MAHVAAA1 FOS1 Unleaded Plus 10,033 0.10 0.19 -0.09 <br /> MAHVAAA2 FOS2 REGULAR UNLEADI 10,033 0.10 0.13 0.04 * <br /> MAHVAAA3 FOS4 Premium Unleaded 10,033 0.10 0.18 -0.09 <br /> MAHVAAA4 FOS5 DIESEL 10,033 0.10 0:13 -0.04 <br /> NOTE: X%1 indicates No Analysis Performed Negative Calculated Leak Rates Indicate Gain <br /> G indicates Gaining trend <br /> 1.The tank owner is required to have a SIR report for each month. <br /> 2.Monthly reports must be submitted to the kxrel agency upon request. <br /> 3.The tank owner is required to have the report by the 20th day of the following month. <br /> 4.If for any reason,the test is neither"Pose nor'fair,the krconclusive column will be marked. <br /> 5.The local agency may need to be notified of the tank that does not pass the SIR test within 24 hours of receipt of the report and the SIR report should be <br /> submitted to the kcal agency within 10 days of the report. <br /> 8.Quantitative and Qualitative Methods: <br /> a.A leak threshold,minimum detectable leak rate,and calculated leak rete must be provided for each tank.If not,then the tank failed the SIR test. <br /> b.If the absolute value of the calculated leak nate for the tank is greater than or equal to the leak threshold and the minimum detectable kick rale Is <br /> I ess than the certified performance standard,OR the absolute value of the calculated leak rete is greater than or equal to the minimum detectable <br /> leak rate and the minimum detectable leak rate is greater than the certified performance standard,the tank failed the SIR test. <br /> c.If the minimum detectable leak role for the tank is greater than the oerti lied performance standard(.e.,0.1 or 0.2 gph)and the absolute value of the <br /> calculated leak rate is leas than the minimum detectable leak rate,the test is Inconclusive for that month. <br /> d.Two consecutive failures and/or incorakusives may require a tank andfor piping integrity test within 15 days from the date of the second report. <br /> The local agency should be contacted. <br /> 7.A conclusive result of'pass'or fair is required to meet monthly leak detection requirements. <br /> Person conducting evattaatwn Simmons Technician <br /> For Information Cath Jim Cartmill Date of SIR Report: 4/27/98 <br />