My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1984-2002
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
505
>
2300 - Underground Storage Tank Program
>
PR0231442
>
COMPLIANCE INFO_1984-2002
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/9/2022 4:49:19 PM
Creation date
6/3/2020 9:49:21 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1984-2002
RECORD_ID
PR0231442
PE
2361
FACILITY_ID
FA0006441
FACILITY_NAME
QUIK STOP MARKET #5124*
STREET_NUMBER
505
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
217-260-21
CURRENT_STATUS
01
SITE_LOCATION
505 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231442_505 N MAIN_1984-2002.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
467
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TEST DATE: 11/06/98 <br />CLIENT: pARADISO MECHANICAL <br />Tank ID: <br />92 1 <br />Product: <br />PREMIUM <br />Capacity in gallons: <br />8,000 <br />Diameter in inches: <br />92.00 <br />Length in inches: <br />282 <br />Material: <br />DW FIBERG <br />COMMENTS <br />PSI at tank bottom: <br />Fluid level in inches: <br />UFT/OFT: <br />Fluid volume in gallons: <br />Tank water level in inches: <br />Test time: <br />Number of thermisters: <br />Specific gravity: <br />Water table depth in inches: <br />Determined by (method): <br />Leak rate in gph: <br />Result: <br />COMMENTS <br />TANK INFORMATION AND <br />t <br />8900 SHOAL CREEK, BUILDING 200 <br />AUSTIN, TEXAS 78757 (512) 451-6334 <br />Tank manifolded: No <br />Vent manifolded: NO <br />Vapor recovery manifolded: yES <br />Overfill protection: yES <br />Overspill protection: YES <br />Installed: ATG <br />CP installed on: / <br />2.00 <br />76.00 <br />UFT <br />7150 <br />0.00 <br />09:53-11:54 <br />5 <br />0.720 <br />NO WELL <br />-0.012 <br />PASS <br />Make: <br />Model: <br />S/N: <br />Open time in sec: <br />Holding psi: <br />Resiliancy cc: <br />est leak rate ml/m: <br />Metering psi: <br />Calib. leak in gph: <br />Results: <br />COMMENTS <br />WORK ORDER NUMBER: 2206556 <br />SITE: QUICK STOP <br />Bottom to top fill in inches: <br />126.0 <br />Bottom to grade in inches: <br />133.0 <br />Fill pipe length in inches: <br />34.0 <br />Fill pipe diameter in inches: <br />4.0 <br />Stage I vapor recovery: <br />DUAL <br />Stage II vapor recovery: <br />BALANCE <br />New/passed Failed/replaced New/passed Failed/replaced <br />L.D. #1 L.D. #1 L.O. #2 L.D. #2 <br />VAPORLESS <br />IM2000 <br />04198 <br />4.00 <br />19 <br />300 <br />189.0 <br />10 <br />3.00 <br />PASS <br />NOT <br />TESTED <br />Test time: <br />12:25-13:13 <br />Matenar <br />DW FIBERG <br />Ullage volume: <br />850 <br />Diameter (in): <br />2.0 <br />Ullage pressure: <br />2.00 <br />Length (ft): <br />45.0 <br />Results: <br />PASS <br />Test psi: <br />50 <br />Bleedback cc: <br />120 <br />Test time (min): <br />30 <br />DATA FOR UTS4T ONLY: <br />Test 1: Start time: <br />10:05 <br />Time of test 1: <br />12:41-12:51 <br />Finish psi: <br />50 NOT NOT NOT <br />Temperature: <br />71.50 <br />Vol change cc: <br />Test 2: Start time: <br />0 TESTED TESTED TESTED <br />Flow rate (cfh): <br />0.200- <br />Finish psi: <br />10:15 <br />so <br />Time of test 2: <br />12:52-13:02 <br />Vol change cc: <br />Test 3: Start time: <br />0 <br />Temperature: <br />71.40 <br />Finish psi: <br />10:25 <br />48 <br />Flow rate (cfh): <br />0.200- <br />Vol change cc: <br />15 <br />Time of test 3: <br />13:03-13:13 <br />Final gph: <br />0.008 <br />Temperature: <br />71.40 <br />Result: <br />PASS <br />Flow rate (cfh): <br />0.200- <br />Pump type: <br />PRESSURE <br />COMMENTS <br />Pump make: <br />FE PETRO <br />COMMENTS <br />Impact Valves Operational: yEs <br />Printed 11A2/1998 12:42 KOHLMEYER <br />
The URL can be used to link to this page
Your browser does not support the video tag.