Laserfiche WebLink
4 <br />TEST DATE: 11/06/98 <br />CLIENT: pARADISO MECHANICAL <br />Tank ID: 89 2 <br />Product: PLUS <br />Capacity in gallons: 10,000 <br />Diameter in inches: 92.00 <br />Length in inches: 352 <br />Material: DW FIBERG <br />COMMENTS <br />PSI at tank bottom: <br />Fluid level in inches: <br />UFT/OFT: <br />Fluid volume in gallons: <br />Tank water level in inches: <br />Test time: <br />Number of thermisters: <br />Specific gravity: <br />Water table depth in inches: <br />Determined by (method): <br />Leak rate in gph: <br />Result: <br />COMMENTS <br />TANK INFORMATION AND <br />8900 SHOAL CREEK, BUILDING 200 <br />AUSTIN, TEXAS 78757 (512) 451-6334 <br />Tank manifolded: NO <br />Vent manifolded: No <br />Vapor recovery manifolded: yES <br />Overfill protection: yEs <br />Overspill protection: yEs <br />Installed: ATG <br />CP installed on: / <br />1.70 <br />65.00 <br />UFT <br />7552 <br />0.00 <br />09:42-11:49 <br />5 <br />0.720 <br />NO WELL <br />-0.019 <br />PASS <br />U <br />Make: <br />Model: <br />S/N: <br />Open time in sec: <br />Holding psi: <br />Resiliancy cc: <br />est leak rate ml/m: <br />Metering psi: <br />Calib. leak in gph: <br />Results: <br />COMMENTS <br />WORK ORDER NUMBER: 2206556 <br />SITE: QUICK STOP <br />Bottom to top fill in inches: <br />126.0 <br />Bottom to grade in inches: <br />134.0 <br />Fill pipe length in inches: <br />34.0 <br />Fill pipe diameter in inches: <br />4.0 <br />Stage 1 vapor recovery: <br />DUAL <br />Stage II vapor recovery: <br />BALANCE <br />New/passed Failed/replaced New/passed Failed/replaced <br />L.D. #1 L.D. #1 L.D. #2 L.D. #2 <br />VAPORLESS <br />LD2000 <br />04196 <br />4.00 <br />18 <br />280 <br />188.0 <br />10 <br />3.00 <br />PASS <br />Test time: <br />12:25-13:16 <br />Material: <br />DW FIBERG <br />Ullage volume: <br />2448 <br />Diameter (in): <br />2.0 <br />Ullage pressure: <br />2.30 <br />Length (ft): <br />45.0 <br />Results: <br />PASS <br />Test psi: <br />5o <br />Bleedback cc: <br />140 <br />Test time (min): <br />30 <br />DATA FOR UTS-4T ONLY: <br />Test 1: Start time: <br />10:20 <br />Time of test 1: <br />12:44-12:54 <br />Finish psi: <br />50 NOT NOT <br />Temperature: <br />71.20 <br />Vol change cc: <br />Test 2: Start time: <br />0 TESTED TESTED <br />Flow rate (cfh): <br />0.200- <br />Finish psi: <br />10:30 <br />50 <br />Time of test 2: <br />12:55-13:05 <br />Vol change cc: <br />0 <br />Temperature: <br />71.10 <br />Test 3: Start time: <br />Finish psi: <br />10:40 <br />Flow rate (cfh): <br />0.200- <br />Vol change cc: <br />49 <br />11 <br />Time of test 3: <br />13:06-13:16 <br />Final gph: <br />0.006 <br />Temperature: <br />71.10 <br />Result: <br />PASS <br />Flow rate (cfh): <br />0.200- <br />Pump type: <br />PRESSURE <br />COMMENTS <br />Pump make: <br />FE PETRO <br />COMMENTS <br />Impact Valves Operational: yES <br />NOT <br />TESTED <br />Printed 11/12/1998 12:42 KOHLMEYER <br />