My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
505
>
2300 - Underground Storage Tank Program
>
PR0231442
>
COMPLIANCE INFO_2010-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/10/2022 10:40:57 AM
Creation date
6/3/2020 9:49:24 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2018
RECORD_ID
PR0231442
PE
2361
FACILITY_ID
FA0006441
FACILITY_NAME
QUIK STOP MARKET #5124*
STREET_NUMBER
505
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
217-260-21
CURRENT_STATUS
01
SITE_LOCATION
505 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231442_505 N MAIN_2010-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
430
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Depth of water level from tank top (inches) <br />Comments: <br />16 <br />17 <br />,. <br />PRODUCT PIPING SUMP TESTING AUG 12 2013 <br />Test Method By: o Manufacturer • Industry Standard o Professional Engr o Other (see below) <br />Test Method Uses: O Pressure O Vacuum • Hydrostatic o Other (see below) <br />Measuring Equipment Used: INCON TS-STS (Electronic Sump Test System) <br />Description <br />Tank #1 <br />Tank #2 <br />Tank #3 <br />10:34 AM <br />Tank product <br />Sump material <br />Gasoline - 89 _ <br />FRP <br />Gasoline - 87 _ <br />FRP <br />Gasoline - 91 <br />FRP <br />4.6447 <br />Test end time <br />Sump diameter (inches) <br />48 <br />48 <br />48 <br />6.4272 <br />3.0338 <br />Sump depth (inches) <br />42 <br />_ <br />41 <br />39 <br />0:15 <br />ion of sump tested <br />Height from tank top to highest <br />piping penetration (inches) <br />14 <br />15 <br />13 <br />Unknown <br />Unknown <br />Height from tank top to lowest <br />electrical penetration (inches) <br />11 <br />10 <br />9 <br />No <br />Was sensor removed for testing? <br />Method of sump attachment to tank <br />Tank Collar <br />Tank Collar <br />Tank Collar <br />Yes <br />Yes <br />Condition of sump prior to testing <br />Dry <br />Dry <br />Dry <br />Port <br />Depth of water level from tank top (inches) <br />Comments: <br />16 <br />17 <br />15 <br />Wait time for water level to stabilize (hrmin) <br />0:10 <br />0:10 <br />0:10 <br />Test start time <br />10:14 AM <br />10:34 AM <br />10:14 AM <br />Initial Probe Reading <br />6.4278 <br />3.0345 <br />4.6447 <br />Test end time <br />10:29 AM <br />10:49 AM <br />10:29 AM <br />Final Probe Reading <br />6.4272 <br />3.0338 <br />4.6443 <br />Test duration (hr:min) <br />0:15 <br />0:15 <br />0:15 <br />ion of sump tested <br />Entire <br />Entire <br />Entire <br />Is system programmed for fail-safe operation? <br />Unknown <br />Unknown <br />Unknown <br />Was fail-safe verified to be operational? <br />No <br />No <br />No <br />Was sensor removed for testing? <br />Yes <br />Yes <br />Yes <br />Was sensor properly replaced after testing? <br />Yes <br />Yes <br />Yes <br />Depth of water level from tank top (inches) <br />Comments: <br />16 <br />17 <br />15 <br />Wait time for water level to stabilize (hrmin) <br />0:10 <br />0:10 <br />0:10 <br />Test start time <br />10:14 AM <br />10:34 AM <br />10:14 AM <br />Initial Probe Reading <br />6.4278 <br />3.0345 <br />4.6447 <br />Test end time <br />10:29 AM <br />10:49 AM <br />10:29 AM <br />Final Probe Reading <br />6.4272 <br />3.0338 <br />4.6443 <br />Test duration (hr:min) <br />0:15 <br />0:15 <br />0:15 <br />Change in water level (t 0.0000 inches) <br />-0.0006 <br />-0.0007 <br />-0.0004 <br />Pass/Fail threshold (10.002 inches / } Hr.) <br />0.0020 <br />0.0020 <br />0.0020 <br />TEST RESULT <br />PASS <br />PASS <br />PASS <br />wig vvaiwn oiyuiccnny, uH:. <br />