My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
505
>
2300 - Underground Storage Tank Program
>
PR0231442
>
COMPLIANCE INFO_2010-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/10/2022 10:40:57 AM
Creation date
6/3/2020 9:49:24 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2018
RECORD_ID
PR0231442
PE
2361
FACILITY_ID
FA0006441
FACILITY_NAME
QUIK STOP MARKET #5124*
STREET_NUMBER
505
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
217-260-21
CURRENT_STATUS
01
SITE_LOCATION
505 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231442_505 N MAIN_2010-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
430
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Depth of water level from UDC bottom (in.) <br />Comments: <br />6 <br />6 <br />UNDER DISPENSER <br />CONTAINMENT DC TE ISTz0. <br />Test Method By: o Manufacturer • Industry Standard o Professional Engr o Other (see below) <br />Test Method Uses: o Pressure o vacuum • Hydrostatic o Other (see below) <br />Measuring Equipment Used: INCON TS -STS (Electronic Sump Test System) <br />Description <br />Disp # 1/2 <br />Disp # 3/4 <br />Initial Probe Reading <br />UDC manufacturer <br />Brave <br />Brave <br />11:31 AM <br />6,1958 <br />11:31 AM <br />5.3471 <br />UDC material <br />Steel <br />Steel <br />Pass/Fail threshold (10.002 inches / 14Hr.) <br />0.0020 <br />UDC depth (inches) <br />9 <br />g <br />PASS <br />Height from UDC bottom to highest <br />piping penetration <br />Bottom <br />Bottom <br />N/A <br />N/A <br />Height from UDC bottom to lowest <br />electrical penetration <br />Bottom <br />Bottom <br />Condition of UDC prior to testing <br />Dry <br />Dry <br />Portion of UDC tested <br />Entire <br />Entire <br />Type of shut -down present <br />Float <br />Float <br />Was sensor removed for testing? <br />N/A <br />N/A <br />Was sensor properly replace <br />Depth of water level from UDC bottom (in.) <br />Comments: <br />6 <br />6 <br />Wait time for water level to stabilize (hr:min) <br />0:05 <br />0:05 <br />Test start time <br />11:16 AM <br />11:16 AM <br />Initial Probe Reading <br />6.1961 <br />5.3474 <br />Test end time <br />Final Probe Reading <br />11:31 AM <br />6,1958 <br />11:31 AM <br />5.3471 <br />Test duration (hr:min) <br />Change in water level (t 0.0000 inches) <br />0:15 <br />-0.0003 <br />0:15 <br />-0.0003 <br />Pass/Fail threshold (10.002 inches / 14Hr.) <br />0.0020 <br />0.0020 <br />TEST RESULT <br />PASS <br />PASS <br />d after testing? <br />N/A <br />N/A <br />Depth of water level from UDC bottom (in.) <br />Comments: <br />6 <br />6 <br />Wait time for water level to stabilize (hr:min) <br />0:05 <br />0:05 <br />Test start time <br />11:16 AM <br />11:16 AM <br />Initial Probe Reading <br />6.1961 <br />5.3474 <br />Test end time <br />Final Probe Reading <br />11:31 AM <br />6,1958 <br />11:31 AM <br />5.3471 <br />Test duration (hr:min) <br />Change in water level (t 0.0000 inches) <br />0:15 <br />-0.0003 <br />0:15 <br />-0.0003 <br />Pass/Fail threshold (10.002 inches / 14Hr.) <br />0.0020 <br />0.0020 <br />TEST RESULT <br />PASS <br />PASS <br />cvio vvmwri anymaenny, mc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.