Laserfiche WebLink
LINE LEAIDETECTOR (LLD) TEIV REPORT <br />TEST DATE: June 29, 2012 <br />Al. FACILITY <br />A2. OWNER <br />Name <br />Quik Stop Market #124 <br />San Joaquin County Environmental Health <br />Name <br />Quik Stop Markets, Inc. <br />Address <br />505 N. Main Street, Manteca, CA 95336 <br />1868 E. Hazelton Avenue, Stockton, CA 95202 <br />Address <br />4567 Enterprise Street, Fremont, CA 94538 <br />Phone # <br />510-657-8500 <br />June 19, 2012 <br />Phone # <br />510-657-8500 <br />Contact <br />Michael Karvelot <br />Stacie Rivera <br />Contact <br />Michael Karvelot <br />A3. C U P A <br />A4. TESTING CONTRACTOR <br />Name <br />San Joaquin County Environmental Health <br />Name <br />Walton Engineering, Inc. <br />Address <br />1868 E. Hazelton Avenue, Stockton, CA 95202 <br />Address <br />P.O. Box 1025, W. Sacramento, CA 95691 <br />Notified <br />June 19, 2012 <br />Lic # <br />617238 A, B, Haz <br />Inspector <br />Stacie Rivera <br />Contact <br />Dulcinea Covan <br />Phone # <br />209-468-8257 <br />Phone # <br />916-373-1166 <br />I. LINE LEAK DETECTOR TEST RESULTS <br />Tank number <br />Product contained _ <br />Leak Detector Type <br />Leak detector make/model <br />Serial number <br />Functional Element Holding (psi) <br />Resiliency (ml) <br />Test leak rate (gph) <br />Pump pressure (psi) <br />Pressure Restriction Reduction (psi) <br />Length of Restriction Test (seconds) <br />Full Flow Opening time (seconds) <br />TEST RESULT <br />Tank number <br />Product contained <br />Leak Detector Type <br />Leak detector make/model <br />Serial number <br />Functional Element Holding (psi) <br />Resiliency (ml) <br />Test leak rate (gph) <br />Pump pressure (psi) <br />Metering pressure (psi) <br />Pressure Restriction Reduction (psi) <br />Length of Restriction Test (seconds) <br />Full Flow Opening time (seconds) <br />TEST RESULT <br />I est Lquipment used <br />1 <br />Gasoline - 87 <br />MLLD <br />Red Jacket FX <br />9234 <br />12 <br />75 <br />3.00 <br />30 <br />8 <br />22 <br />30 <br />3 <br />PASS <br />J. COMMENTS: <br />Adjusted the 89 VMI MLLD, retested with passing results. <br />VMI LUI-S9U <br />3 <br />Gasoline - 91 <br />MLLD <br />FE Petro STP -MLD <br />1121043 <br />13 _ <br />-- 125 <br />3.00 <br />2 <br />Gasoline - 89 <br />MLLD <br />VMI 99LD-2000 <br />4051056 <br />40 <br />45 <br />3.00 <br />40 <br />22 <br />18 <br />30 <br />4 <br />PASS <br />24 <br />9 <br />15 <br />30 <br />7 <br />PASS <br />1 W� WALTON <br />Signature: UI <br />ENGINEERING, INC. <br />Technician: Jessie Wadkins / B35391 5307886 -UT Date: June 29, 2012 <br />