Laserfiche WebLink
ANNUAL 4WILL CONTAINER TESS REPORT <br />TEST DATE: June 29, 2012 <br />A1. FACILITY <br />Name Quik Stop Market #124 <br />Address 505 N. Main Street, Manteca, CA 95336 <br />Phone # 510-657-8500 <br />Contact Michael Karvelot <br />A2. OWNER <br />Name Quik Stop Markets, Inc. <br />Address 4567 Enterprise Street, Fremont, CA 94538 <br />Phone # 510-657-8500 <br />Contact Michael Karvelot <br />A3. C U P A <br />A4. TESTING CONTRACTOR <br />Name <br />San Joaquin County Environmental Health <br />Name <br />Walton Engineering, Inc. <br />Address <br />1868 E. Hazelton Avenue, Stockton, CA 95202 <br />Address <br />P.O. Box 1025, W. Sacramento, CA 95691 <br />Notified <br />June 19, 2012 <br />Lic # <br />617238 A, B, Haz <br />Inspector <br />Stacie Rivera <br />5 <br />Contact <br />Dulcinea Coven <br />Phone # <br />209-468-8257 <br />OPW <br />Phone # <br />916-373-1166 <br />K. SPILL CONTAINER TEST RESULTS <br />Measuring Equipment Used: Caldwell System 2001 / Walton Engineering (Level Change Indicator) <br />3 <br />Tank Number <br />1 <br />2 <br />Product contained <br />Gasoline - 87 <br />Gasoline - 89 <br />Gasoline - 91 <br />Spill container capacity (US gallons) <br />5 <br />5 <br />5 <br />_ <br />Spill container manufacturer <br />OPW <br />OPW <br />OPW <br />Spill container depth (inches) <br />15.00 <br />15.00 <br />14.50 <br />Is the spill container located in a sump? <br />Yes <br />Yes <br />Yes <br />Does sump have a liquid sensor installed? <br />No <br />No <br />No <br />Condition of spill container prior to testing <br />Dry <br />Dry <br />Dry <br />Portion of spill container tested <br />Entire <br />Entire <br />Entire <br />13.00 _ <br />13.50 <br />13.50 <br />Depth of water level from bottom (inches) <br />Wait time for water level to stabilize (hr:min) <br />0:05 <br />0:05 <br />0:05 <br />Test start time <br />10:11 <br />9:35 <br />10:55 <br />Test end time <br />10:41 <br />10:05 <br />10:57 <br />_ <br />Test duration (hr:min) <br />0:30 <br />0:30 <br />0:02 <br />Change in water level (t 0.000 inches) <br />0.000 <br />0.000 <br />0.500 <br />Pass/Fail threshold (0.005 inches /'/2 Hr.) <br />0.005 <br />_ <br />0.005_ <br />0.005 <br />TEST RESULT <br />PASS <br />_ <br />PASS <br />FAIL <br />L. COMMENTS: <br />The 91 OPW multi -port spill container (new style) failed at the bucket. <br />Replaced the 87 OPW fill cap. <br />(,)JL— WALTON <br />Signature: ENGINEERING, INC. <br />Technician: Jessie Wadkins I B35391 5307886 -UT Date: .lune 29, 2012 <br />