My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
505
>
2300 - Underground Storage Tank Program
>
PR0231442
>
COMPLIANCE INFO_2010-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/10/2022 10:40:57 AM
Creation date
6/3/2020 9:49:24 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2018
RECORD_ID
PR0231442
PE
2361
FACILITY_ID
FA0006441
FACILITY_NAME
QUIK STOP MARKET #5124*
STREET_NUMBER
505
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
217-260-21
CURRENT_STATUS
01
SITE_LOCATION
505 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231442_505 N MAIN_2010-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
430
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov.orCl/ehd <br /> `de ground Storage Tank Program Inspection Report :$ <br /> Facility Name: Facility Address: Date: <br /> QUIK STOP MARKET#5124* 505 N MAIN ST, MANTECA June 16,2017 <br /> 1 SUMM ARY OF�f10LAT10NS" <br /> �.. , E GC#lkS3 6 CIASS 11,orNHQR-Nonce to Comptyl. <br /> Item# Remarks <br /> 209 CCR 2715(c)Designated operator did not inspect all required items and/or the inspection reports not completed. <br /> The designated operator failed to check and note the correct test dates. For the 9/7/2016, 1/3/2017,2/1/2017 and <br /> the 3/1/2017 designated operator(DO)monthly inspection reports,the incorrect date(8/07/2013)was entered for <br /> the secondary containment testing. For the 10/12/2016. 11/7/2016, 12/1/2016,4/3/2017, 5/1/2017, and 6/1/2017 <br /> DO monthly inspection reports,the incorrect date(6/18/2017)was entered for the secondary containment testing. <br /> The correct date for that test was 8/17/2016. <br /> For the 7/5/2016 DO monthly inspection report,the incorrect date(4/20/2015)was entered for the spill container <br /> test. The correct date for that test was 6/16/2016. <br /> For the 7/5/2016, 12/1/2016,4/3/2017 and 5/1/2017 DO monthly inspection reports,the incorrect expiration date <br /> was entered for the Curtis Carpenter's DO ICC license expiration date. The 7/5/2016 DO report shows that the DO <br /> license expired on 6/16/2015 and the 12/1/2016 DO report shows that the DO license expired on 3/20/2015. The <br /> 4/3/2017 and the 5/1/2017 DO inspection report shows that the DO license expired on 2/5/2019 when the correct <br /> date is 2/6/2019. <br /> During the monthly inspection,the designated operator shall check that all required testing and maintenance for the <br /> UST system have been completed and document the dates they were done. Ensure that designated operators <br /> performing monthly inspections at this facility are including all of the required information on the reports. <br /> This is a minor violation. <br /> 211 CCR 2715(f) Designated operator employee training not performed or log not kept. <br /> The designated operator employee training log for Jass Singh did not not include the hiring date. According to Sat <br /> Singh(manager),Jass was hired after July 1,2005. After July 1, 2005,the hiring dates need to be included with the <br /> employee training date. <br /> Ensure that employees have been trained by the designated operator, maintain the list on site, and include the hiring <br /> dates. <br /> This was corrected on site. <br /> This is a repeat violation, Class II. <br /> 309 CCR 2636(f)(1)Monitoring in sump/UDC failed to activate an audible and visual alarm or stop the flow product. <br /> The Bravo Float and Chain for the 87 product in the 1/2 under dispenser containment unit(UDC)sump failed to stop <br /> the flow of product at the dispenser when tested. All monitoring equipment shall be maintained to activate an <br /> audible and visual alarm or stop the flow of product at the dispenser when it detects a leak.The service technician <br /> adjusted the chain and verified functionality. <br /> This was corrected on site. <br /> This is a repeat violation, Class II. <br /> FA0006441 PR0231442 SCO01 06/16/2017 <br /> EHD 23-01 Rev.09/22/16 Page 4 of 5 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.