Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov.org/ehd <br /> Underground Storage Tani Programylnspecuon Report <br /> Facility Name: Facility Address: Date: <br /> QUIK STOP MARKET#5124* 505 N MAIN ST, MANTECA June 16, 2017 <br /> SUMMARY OF VIOLATIONS <br /> (GLASS 1,GLASS It;or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 315 HSC 25291(e)Water in secondary containment not removed, analyzed, and properly disposed of(pre-Jul 2003). <br /> Approximately 2 cups of liquid was observed in the 87 product-submersible turbine pump(STP)sump and 1/3 cup <br /> of liquid in the 91 STP sump. Approximately 34 gallons of liquid was observed in the 87 fill sump and 3 cups of <br /> liquid in the 89 fill sump. The service tech removed the liquid from all of the STP and fill sumps. If water could enter <br /> into the secondary containment by precipitation or infiltration, it must be removed and disposed of properly. Ensure <br /> that all sumps and annular spaces are maintained free of liquid. <br /> This was corrected on site. <br /> This is a repeat violation, Class II. <br /> 318 CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi. <br /> The 89 product VMI line leak detector failed to detect a leak when tested. All line leak detectors shall be capable of <br /> detecting a 3-gallon per hour leak at 10 psi. The service technician adjusted the leak detector, retested it, and it <br /> passed. <br /> This was corrected on site. <br /> This is a repeat violation, Class II. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by July 16, 2017 . <br /> Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br /> documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br /> Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer(if <br /> applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br /> Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br /> AFTER THE COMPLIANCE DATE,EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING <br /> THIS FACILITY BACK INTO COMPLIANCE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received by: Date: June 16, 2017 Inspector: Inspector Phone: <br /> Printed Name and Title: JOHN ALANIZ, EHS Trainee (209)468-3147 <br /> Satwinder Singh, Franchisee <br /> FA0006441 PR0231442 SCO01 06/16/2017 <br /> EHD 23-01 Rev.09/22/16 Page 6 of 5 Underground Storage Tank Program OIR <br />