My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1997-2006
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1700
>
2300 - Underground Storage Tank Program
>
PR0231454
>
COMPLIANCE INFO_1997-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/16/2023 12:42:13 PM
Creation date
6/3/2020 9:49:35 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1997-2006
RECORD_ID
PR0231454
PE
2361
FACILITY_ID
FA0003796
FACILITY_NAME
Manteca Valero
STREET_NUMBER
1700
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22802002
CURRENT_STATUS
01
SITE_LOCATION
1700 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231454_1700 E YOSEMITE_1997-2006.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
437
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
v D.Results of Testing/Servicing 0 <br /> Software Version Installed: <br /> Complete the following checklist: <br /> t."I Yes ❑ No* Is the audible alarm operational? <br /> ox Yes No* Is the Visual alarm operational? <br /> x Yes No* Were all sensors visually inspected,functionally tested,and confirmed operational? <br /> x Yes ❑ No* Were all sensors installed at the lowest point of secondary containment and positioned so that other <br /> equipment will not interfere with their proper operation? <br /> Yes No* If alarms are relayed to a remote monitoring station,is all communications equipment(e.g.modem) <br /> HxN/A operational? <br /> x Yes ❑ No* For pressurized piping systems,does the turbine automatically shut down if the piping secondary <br /> ❑N/A containment monitoring system detects a leak,fails to operate,or is electrically disconnected?If yes: <br /> which sensors irritate positive shut-down? [�O Sump/Trench Sensors[x]Dispenser Containment Sensors <br /> Did you confirm positive shut-down due to leaks and sensor failure/disconnected? [x] Yes; ❑ No; <br /> [X] Yes ❑ No* For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e.no <br /> ❑N/A mechanical overfill prevention valve is installed),is the overfill warning alarm visual and audible at <br /> the tank fill point(s)and operating properly?If so,at what percent of tank capasity does the alarm <br /> trigger? � % <br /> Yes* U No Was any monitoring equipment replaced?If Yes,identify specific sensors,probes,or other equipment <br /> replaced and list the manufacturer name and model for all replacement parts in Section E,below. <br /> ❑ Yes* ❑ No Was liquid found inside any secondary containment systems designed as dry systems? <br /> ❑Product; ❑ Water.If yes,describe causes in Section E,below. <br /> xNo* Was monitoring system set-up reviewed to ensure proper settings?Attach set-up reports,if applicable. <br /> x Yes No* Is all monitoring equipment operational per manufacturer's specifications? <br /> *In Section E below,discribe how and when these deficiencies were or will be corrected. <br /> E. Comments: <br />