Laserfiche WebLink
RECEIVE <br /> Z014 <br /> Reliable Petroleum Services, Inc. M r C Lr <br /> age <br /> IN-TANK SETUP T 2:91 OCTANE <br /> - - - - - - - - - - - -I PRODUCT CODE 2 LEAK TEST METHOD <br /> T 1 :87 OCTANE THERMAL COEFF : •000700 TEST ON DATE ALL TANK <br /> PRODUCT CODE I TANK DIAMETER 95.75 <br /> THERMAL COEFF ': .000700 TANK PROFILE 4 PTS JAN 29. 2009 <br /> TANK DIAMETER 95.75 FULL VOL 12032 START TIME : DISABLED <br /> TANK PROFILE 4 FTS 71 .8 INCH VOL 9697 TEST RATE :0.20 GAL/HR <br /> 47.9 INCH VOL : 6056 DURATION 2 HOURS <br /> FULL VOL 12032 23.9 INCH VOL 2386 <br /> 71 .8 INCH VOL 9697 TST EARLY STOP:DISABLED <br /> 47.9 INCH VOL 6056 <br /> 23.9 INCH VOL 2386 FLOAT SIZE: 4.0 IN. LEAK, TEST REPORT FORMAT <br /> NORMAL <br /> FLOAT SIZE: 4.0 IN. WATER WARNING 1 .5 10 <br /> HIGH WATER LIMIT: 2.0 <br /> WATER WARNING 1 .5 MAX OR LABEL VOL: 12032 <br /> HIGH WATER LIMIT: 2.0 OVERFILL LIMIT 90% <br /> MAX OR LABEL VOL: 12032 HIGH PRODUCT 10958 <br /> OVERFILL LIMIT 90% 11430 <br /> HIGH PRODUCT 1095%8 DELIVERY LIMIT 20% <br /> 11430 2406 <br /> DELIVERY LIMIT 20% LOW PRODUCT 1000 LIQUID SENSOR SETUP <br /> 2406 LEAK ALARM LIMIT: 50 - - - - - - - - - - - - <br /> LOW PRODUCT 1000 SUDDEN LOSS LIMIT: 50 <br /> LEAK ALARM LIMIT: 50 TANK TILT 6.00 L 1 :DISPENSER 1-2 <br /> SUDDEN LOSS LIMIT: 50 PROBE OFFSET 0.00 TRI-STATE (SINGLE FLOAT) <br /> TANK TILT 4.00 CATEGORY : DISPENSER PAN <br /> PROBE OFFSET 0.00 SIPHON MANIFOLDED TANKS <br /> T#: NONE <br /> SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS L 2:DISPENSER 3-4 <br /> T#: NONE T#: NONE TRI-STATE (SINGLE FLOAT) <br /> LINE MANIFOLDED TANKS CATEGORY : DISPENSER PAN <br /> T#: NONE LEAK MIN PERIODIC: 0% <br /> 0 <br /> L 3:DISPENSER 5-6 <br /> LEAK. MIN PERIODIC: 0 LEAK MIN ANNUAL 20% TRI-STATE (SINGLE FLOAT) <br /> 0 <br /> 2406 CATEGORY : DISPENSER PAN <br /> . <br /> LEAK MIN ANNUAL 20% <br /> 2406 PERIODIC TEST TYPE <br /> STANDARD L 4:DISPENSER 7-8 <br /> PERIODIC: TEST TYPE TRI-STATE (SINGLE FLOAT) <br /> STANDARD ANNUAL TEST FAIL CATEGORY : DISPENSER PAN <br /> ALARM DISABLED <br /> ANNUAL TEST FAIL PERIODICTEST FAIL <br /> ALARM DISABLED ALARM DISABLED L 5:87 SUMP <br /> PERIODIC TEST FAIL TRI-STATE (SINGLE FLOAT) <br /> ALARM DISABLED GROSS TEST FAIL CATEGORY . ,STP SUMP <br /> ALARM DISABLED <br /> GROSS TEST FAIL ANN TEST AVERAGING: OFF <br /> ALARM DISABLED L 6:87 ANNULAR <br /> PER TEST AVERAGING: OFF TRI-STATE (SINGLE FLOAT) <br /> ANN TEST AVEkAGING: OFF TANK TEST NOTIFY: OFF CATEGORY : ANNULAR SPACE <br /> PER TEST AVERAGING: OFF <br /> TANK TEST NOTIFY: OFF TNK TST SIPHON BREAKOFF <br /> L 7:91 SUMP <br /> DELIVERY' DELAY 3 MIN TRI-STATE (SINGLE FLOAT) <br /> TNK TST SIPHON BREAK OFF PUMP THRESHOLD 10.00% CATEGORY : STP SUMP <br /> DELIVERY DELAY 3 MIN <br /> PUMP THRESHOLD 10.00% <br /> L 8:91 ANNULAR <br /> TRI-STATE (SINGLE FLOAT) <br /> CATEGOR`! : ANNULAR SPACE <br />