My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2007-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1700
>
2300 - Underground Storage Tank Program
>
PR0231454
>
COMPLIANCE INFO_2007-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/29/2023 11:52:51 AM
Creation date
6/3/2020 9:49:39 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2018
RECORD_ID
PR0231454
PE
2361
FACILITY_ID
FA0003796
FACILITY_NAME
Manteca Valero
STREET_NUMBER
1700
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22802002
CURRENT_STATUS
01
SITE_LOCATION
1700 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231454_1700 E YOSEMITE_2007-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
466
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RECE/VeD <br /> SEP 0 4 2014 <br /> Reliable Petroleum Services, Inc. <br /> rc <br /> Page'5-of R V <br /> LIQUID SENSOR ALMS EVRi I SD SETUP <br /> OUTPUT RELAY SETUP L 1 :FUEL ALARM <br /> — — — — — — — — — — — — L2:FUELALARM <br /> L 3:FUEL ALARM EVR TYPE: BALANCE <br /> R 1 :87 RELAY L 4:FUEL ALARM <br /> TYPE: L 7:FUEL ALARM BALANCE NOZZLE TYPE <br /> STANDARD L B:FUEL ALARM VST <br /> NORMALLY CLOSED L 2:SENSOR OUT ALARM <br /> L 3:SENS0R OUT ALARM VAPOR PROCESSOR TYPE <br /> TANK #: 1 L 7:SENSOR OUT ALARM ALARM VEEDER—ROOT POLISHER <br /> L 8:SENSOR OUT ALARM <br /> IN—TANK ALARMS L 1 :SHORT ALARM ANALYSIS TIMES® <br /> T 1 :LEAK ALARM L 2:SH0RT ALARM <br /> 00 AM <br /> T 1 :HIGH WATER ALARM L 3:SH0RT ALARM DELAY <br /> 1f MINUTNUTESS:: <br /> T 1 :L0W PRODUCT ALARM L 4:SHORT ALARM1 <br /> T 1 :SUDDEN LOSS ALARM L 8:SHORT ALARM <br /> T 1 :PERI0DIC TEST FAIL <br /> ISD SITE ALARMS ACCEPT HIc,H ORVR: <br /> LIQUID SENSOR ALMS ISD GROSS PRES FAIL DISABLED <br /> L 1 :FUEL ALARM ISD DEGRD FRES FAIL ISD HOSE TABLE <br /> L 2:FUEL ALARM ISD VAPOR LEAK FAIL ID FP FL HL AA RR <br /> L 3:FUEL ALARM ISD VP FRES FAIL <br /> L 4:FUEL ALARM ISD VP STATUS FAIL 01 01--01 02--01 UU-- <br /> L 5:FUEL ALARM O1 O1 O1 02 01 UU <br /> L 6:FUEL ALARM ISD HOSE ALARMS <br /> 02 02 02 02 O1 UU <br /> L 2:SENS0R OUT ALARM ALL:FLOW COLLECT FAIL 03 03 03 02 02 UU <br /> L 3:SENS0R OUT ALARM 04 04 04 02 02 UU <br /> L 4:SENS0R OUT ALARM 05 05 05 02 03 UU <br /> L 5:SENS0R OUT ALARM 06 06 06 02 03 UU <br /> L 1 :SHORT ALARM 07 07 07 02 04 UU <br /> L 2:SH0RT ALARM 08 08 08 02 04 UU <br /> L 3:SH0RT ALARM <br /> L 4:SHORT ALARM <br /> L 5:SH0RT ALARM ID <br /> AIRFLOW METER MAP <br /> ID SERIAL NUM LABEL <br /> ISD SITE ALARMS ------------------------ <br /> ISD GROSS PRES FAIL 1 39579 VFM 1-2 <br /> ISD DEGRD PRES FAIL SMARTSENSOR SETUP <br /> 2 39901 VFM 3-4 <br /> ISD VAPOR LEAK FAIL — — — — — — — — — — — — 3 39580 VFM 5-6 <br /> ISD VP PRES FAIL 4 39900 VFM 7-8 <br /> ISD VP STATUS FAIL 5 1 :VFM 1-2 <br /> ISD HOSE ALARMS CATEGORY AIR FLOW METER ISD FUEL GRADE HOSE MAP <br /> ALL:FLOW COLLECT FAIL 5 2:VFM 3-4 1 2 3 4 <br /> CATEGORY AIR FLOW METER FP MHH MHH MHH MHH AA <br /> R 2:91 RELAY ----------------- <br /> 01 101 901 201 U U 1 <br /> TYPE: 5 3:VF(°i 5-6 02 102 902 202 U U 1 <br /> STANDARD CATEGORY AIR FLOW METER <br /> NORMALLY CLOSED 03 103 903 203 U U 2 <br /> 5 4:VFM 7-8 04 104 904 204 U U 2 <br /> TANK: #: 2 CATEGORY AIR FLOW METER 05 105 905 205 U U 306 106 906 206 U U 3 <br /> 5 6:VPS 3-4 07 107 907 207 U U 4 <br /> IN—TANK ALARMS CATEGORY VAPOR PRESSURE 08 108 908 208 U U 4 <br /> T 2:LEAK ALARM <br /> T 2:HIGH WATER ALARM 5 7:CANISTER LABEL TABLE <br /> T 2:L0W PRODUCT ALARM CATEGORY VAPOR VALVE <br /> T 2:SUDDEN LOSS ALARM ------------------------ <br /> T 2:PERIODIC TEST FAIL YEN1 : UNASSIGNED <br /> CATEGORATM P SENSOR 2: BLEND3 <br /> 3: REGULAR <br /> 4: MID GRADE <br /> 5: PREMIUM <br /> 6: GOLD <br /> 7: BRONZE <br /> 8: SILVER <br /> 9: BLEND2 <br /> 10: BLEND4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.