My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2007-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1700
>
2300 - Underground Storage Tank Program
>
PR0231454
>
COMPLIANCE INFO_2007-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/29/2023 11:52:51 AM
Creation date
6/3/2020 9:49:39 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2018
RECORD_ID
PR0231454
PE
2361
FACILITY_ID
FA0003796
FACILITY_NAME
Manteca Valero
STREET_NUMBER
1700
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22802002
CURRENT_STATUS
01
SITE_LOCATION
1700 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231454_1700 E YOSEMITE_2007-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
466
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Amok <br />SWRCB, January 2002 Page of <br />4. TANK ANNULAR TESTING <br />Test Method Developed By: X Tank Manufacturer ❑ Industry Standard ❑ Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: ❑ Pressure X Vacuum ❑ Hydrostatic <br />Test Result: X Pass 0 FailX Pass' ❑ Fail Pass 0 Fail 0 Pass ❑;Fail <br />Was sensor removed for testing? X Yes ❑ No ❑ NA X Yes ❑ No ❑ NA Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA <br />Was sensor properly replaced and X Yes ❑ No ❑ NA X Yes ❑ No ❑ NA Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA <br />verified functional after testin ? <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />' Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br />containment, such as systems that are hydrostatically monitored or under constant vacuum, are exempt from periodic containment <br />testing. {California Code of Regulations, Title 23, Section 2637(a)(6)} <br />Page 2 of 7 <br />❑ Other (Spec) <br />Test Equipment Used: Gast Vacuum Pump/Vacuum Gauges in Hg. <br />Equipment Resolution: -1/2-301-1g. <br />Em MEMO= <br />MENNEEM <br />Tank # 1 <br />Tank # 2 <br />Tank # <br />Tank # <br />Is Tank Exempt From Testing?' <br />❑ Yes x No <br />❑ Yes x No <br />❑ Yes No <br />❑ Yes ❑ No <br />Tank Capacity: <br />12K <br />12K <br />Jacketed Double <br />Jacketed Double <br />Tank Material: <br />Wall Steel <br />Wall Steel <br />Tank Manufacturer: <br />Modern Welding <br />Modern Welding <br />Product Stored: <br />Regular 87 <br />Supreme 91 <br />Wait time between applying <br />1 Hour <br />1 Hour <br />vacuum and starting test: <br />Test Start Time: <br />2:05 <br />2:25 <br />Initial Reading (Rj): <br />-5 Hg. <br />-5 Hg. <br />Test End Time: <br />3:05 <br />3:25 <br />Final Reading (RF): <br />-5 Hg. <br />-5 Hg. <br />Test Duration: <br />1 Hour <br />1 Hour <br />Change in Reading (RF -RI): <br />OHg. <br />0 Hg. <br />Pass/Fail Threshold or Criteria: <br />No loss in Hg. <br />No loss in Hg. <br />Test Result: X Pass 0 FailX Pass' ❑ Fail Pass 0 Fail 0 Pass ❑;Fail <br />Was sensor removed for testing? X Yes ❑ No ❑ NA X Yes ❑ No ❑ NA Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA <br />Was sensor properly replaced and X Yes ❑ No ❑ NA X Yes ❑ No ❑ NA Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA <br />verified functional after testin ? <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />' Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br />containment, such as systems that are hydrostatically monitored or under constant vacuum, are exempt from periodic containment <br />testing. {California Code of Regulations, Title 23, Section 2637(a)(6)} <br />Page 2 of 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.