Laserfiche WebLink
SWRCB, January 2002 <br />6. PIPING SUMP TESTING <br />Page of <br />Test Method Developed By: ❑ Sump Manufacturer ❑ Industry Standard X Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: ❑ Pressure ❑ Vacuum X Hydrostatic <br />❑ Other (Spec) <br />Test Equipment Used: Caldwell Level Change Indicator <br />Equipment Resolution: .002 <br />Sump # 1 <br />Sump # 2 <br />Sump # <br />Sump # <br />Sump Diameter: <br />46" Hexagon <br />46" Hexagon <br />Sump Depth: <br />44" <br />41" <br />Sump Material: <br />Fiberglass <br />Fiberglass <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />Product 24" <br />Product 18" <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />18" <br />16" <br />Condition of sump prior to testing: <br />Dry <br />Dry <br />Portion of Sump Tested' <br />Water Level 26" <br />Water Line 20" <br />Does turbine shut down when <br />sump sensor detects liquid (both <br />product and water)?' <br />X Yes ❑ No ❑ NA <br />X Yes ❑ No [INA <br />Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />Turbine shutdown response time <br />Not Alarmed <br />Not Alarmed <br />Is system programmed for fail-safe <br />shutdown?" <br />X Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA <br />Yes ❑ No ❑ NA <br />❑ Yes ❑ No [INA <br />Was fail-safe verified to be <br />operational?* <br />Yes X No ❑ NA <br />Yes X No ❑ NA <br />Yes No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />Wait time between applying water <br />and starting test: <br />10 Minutes <br />10 Minutes <br />Test Start Time: <br />2:05 <br />1:15 <br />Initial Reading (Ri): <br />.001 <br />.001 <br />Test End Time: <br />2:35 <br />1:45 <br />Final Reading (RF): <br />.001 <br />.001 <br />Test Duration: <br />30 Minutes <br />30 Minutes <br />Change in Reading (RF -R,): <br />0 <br />0 <br />Pass/Fail Threshold or Criteria: <br />.005/30 Minutes <br />.005/30 Minutes <br />Test Result: <br />X Pass ❑ Fail <br />X Pass ❑ Fail <br />Pass ❑ Fail <br />❑ Pass ❑'Fail <br />Was sensor removed for testing? <br />X Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA <br />Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />X Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA <br />Yes ❑ No ❑ NA <br />11 Yes ❑ No El NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />' If the entire depth of the sump is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />Page 4 of 7 <br />