My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2007-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1700
>
2300 - Underground Storage Tank Program
>
PR0231454
>
COMPLIANCE INFO_2007-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/29/2023 11:52:51 AM
Creation date
6/3/2020 9:49:39 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2018
RECORD_ID
PR0231454
PE
2361
FACILITY_ID
FA0003796
FACILITY_NAME
Manteca Valero
STREET_NUMBER
1700
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22802002
CURRENT_STATUS
01
SITE_LOCATION
1700 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231454_1700 E YOSEMITE_2007-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
466
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />600 East Main Street, Stockton, California 95202-3029 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.siciov.org/ehd/unitiii.htmi <br />CONTINUATION FORM <br />Page: 3 of 4 <br />OFFICIAL INSPECTION REPORT <br />Date: 07/20/10 <br />Facility Address: Statewide Petrol Inc. 1700 E. Yosemite Ave. Manteca, CA 95336 <br />Program: UST <br />SUMMARY OF VIOLATIONS <br />CLASS I, CLASS 11, or MINOR -Notice to Comp <br />On site to conduct the routine inspection and witness the annual monitoring system certification. <br />Violations: 3, 4, 5, 17, 21, 23a, 23c. Repeat Violations- 7, 24. <br />Violations-. <br />#3 UST facility and tank forms on file with the EHD are not current. Any change of information on these <br />forms must be submitted to the EHD within 30 days of the changes. Immediately complete and submit a <br />copy of the facility and tank forms to the EHD. Complete a separate tank form for each tank. <br />Note: Forms provided. <br />#4 Financial responsibility documents have not been submitted to the EHD. Current financial <br />responsibility documents are required to be submitted annually. Complete and submit a copy of the <br />financial responsibility by 8-20-10. Note- Forms provided. <br />#5 The response plan on site is not current. The response plan must be current and approved by the <br />EHD. Complete and submit a copy of the response plan for approval by the EHD by 8-20-10. An <br />approved copy will be returned for your records. Note: Form provided. <br />#17 The 87 line leak detector failed to detect a leak when tested. All line leak detectors shall be capable <br />of detecting a 3 -gallon per hour leak at 10 psi. The service technician adjusted the leak detector, <br />retested it, and it passed. <br />#23a A new designated operator was hired on May 2008 and notification was not provided to the EHD <br />within 30 days of the change. Any changes shall be reported to the EHD with 30 days. Submit <br />notification to the EHD identifying all the designated operators for this facility by 8-20-10. Note-. Owner <br />Statements of Designated UST Operator and Understanding of and Compliance w/ UST requirements <br />form provided. <br />#23c The designated operator failed to document all the alarms for the previous month on the Sep. 2009 <br />and Feb. 2010 designated operator monthly inspection reports. The missing alarms include- L1: Disp. 1- <br />2 sensor out on 9-19-09 and 1-31-10. During the monthly inspection, the designated operator shall <br />review the alarm history for the previous month, check that each alarm was documented and responded <br />to appropriately, and attach a copy of the alarm history with documentation taken in response to any <br />alarms to the monthly report. Ensure that designated operators performing monthly inspections at this <br />facility are including all of the required information on the reports. <br />ALL EHD STAFF TOLE ASSOCIATED WITH FAILING To coYPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE ($115). <br />THIS FACILITY IS SUBJECT TO REINS PE ON AT JNY TIME AT END'S CURRENT HOURLY RATE. <br />EHD Inspector <br />Ived By. <br />T = <br />EHD 23-02-003 Rev 06/01/10 \ CONTINUATION FORM <br />
The URL can be used to link to this page
Your browser does not support the video tag.