My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2007-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1700
>
2300 - Underground Storage Tank Program
>
PR0231454
>
COMPLIANCE INFO_2007-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/29/2023 11:52:51 AM
Creation date
6/3/2020 9:49:39 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2018
RECORD_ID
PR0231454
PE
2361
FACILITY_ID
FA0003796
FACILITY_NAME
Manteca Valero
STREET_NUMBER
1700
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22802002
CURRENT_STATUS
01
SITE_LOCATION
1700 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231454_1700 E YOSEMITE_2007-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
466
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />600 East Main Street, Stockton, California 95202-3029 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sigov.orp/ehd/unitiii.htmi <br />CONTINUATION FORM <br />Page: 4 of 4 <br />OFFICIAL INSPECTION REPORT <br />Date: 07/20/10 <br />Facility Address: Statewide Petrol Inc. 1700 E. Yosemite Ave. Manteca, CA 95336 <br />Program: UST <br />SUMMARY OF VIOLATIONS <br />CLASS I, CLASS II, or MINOR -Notice to Comply) <br />#23c The designated operator failed to check and note the correct test dates for the secondary <br />containment test on the June 2009 through 2010 designated operator monthly inspection reports. <br />Designated Operator listed 9-10-07 as the test date. 9-20-07 should have been listed. On the 11-16-09 <br />D. O. report, no date was listed for the secondary containment test. During the monthly inspection, the <br />designated operator shall check that all required testing and maintenance for the UST system have been <br />completed and document the dates they were done. Ensure that designated operators performing <br />monthly inspections at this facility are including all of the required information on the reports. <br />#21 Liquid was observed in the 87 stp sump. If water could enter into the secondary containment by <br />precipitation or infiltration, it must be removed and disposed of properly. Immediately remove this liquid, <br />make a hazardous waste determination per Title 22 hazardous waste regulations, and manage it <br />accordingly. Ensure that the 87 stp sump is maintained free of liquid. Technician corrected during the <br />inspection by removing the liquid and placed it into the hazardous waste drum on site. <br />Repeat Violations: <br />#7 The maintenance records for the following alarms: L1: Disp. 1-2 sensor out alarm of 9-19-09, <br />12-17-09, 1-14-10, 1-31-10, and L4 Disp. 7-8 fuel alarm of 2-23-10 were not found on site. These <br />records shall be kept on site for at least 3 years. Immediately locate and maintain the maintenance <br />records for the following alarms: L1: Disp. 1-2 sensor out alarm of 9-19-09, 12-17-09, 1-14-10, 1-31-10, <br />and L4 Disp. 7-8 fuel alarm of 2-23-10 on site and submit copies to the EHD by 8-20-10. <br />#24 Annual monitoring system certification, leak detector testing, and spill container testing was <br />performed on 7-13-09 and a test report has not been submitted to the EHD. A copy of the test report <br />must be submitted within 30 days of the tests. Immediately submit a copy of the test report to the EHD. <br />ALL EHD STAFF TWE ASSOCIATED VA H FAILING TO COMPLY BY THE ABOVE NOTED DATES YMLL BE BILLED AT THE CURRENT HOURLY RATE ($115). <br />THIS FACILITY IS SUBJECT TO REINS EC-n)DV AT ANY TIME AT END'S CURRENT HOURLY RATE. <br />EHD Inspect7 <br />R BY: <br />Title:1 <br />EHD 23-02-003 Rev 06/01/10 CONTINUATION FORM <br />
The URL can be used to link to this page
Your browser does not support the video tag.