Laserfiche WebLink
UNwD PROGRAM CONSOLIDATED Fem <br /> r2,Vjt TANKS <br /> UNDERGROUND STORAGE TANKS -TANK P 1 (two pages per tank) <br /> v Page 'o of <br /> TYPE OF ACTION Fl. NEW SITE PERMIT F 4. AMENDED PERMIT F 5. CHANGE OF INFORMATION) I RARY SITE CLOSURE <br /> (Check one item only)F 2. OPERATOR CHANGE F 7. PERMANENTLY CLOSED ON SITE <br /> X 3. RENEWAL PERMIT (Specify reason-for local use only) (Specify change-for local use only) r 8. TANF K REMOVED 430 <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As)3 FACILITY ID# 1 <br /> Ripon Shell <br /> LOCATION WITHIN SITE(Optional)431 341 E. Main Street, Ripon, CA 95366 <br /> I.TANK DESCRIPTION (A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the focal agency.) <br /> TANK ID# /_ 114�D��a 432 TANK MANUFACTURER 433 COMPARTMENTALIZED TANK F Yes X No 434 <br /> 135816-Premium Xerxes If AYes--,complete one page for each compartment. <br /> DATE INSTALLED(YEAR/MO) 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS 437 <br /> 1996 15,000 On <br /> ADDITIONAL DESCRIPTION(For local use only) 438 <br /> II.TANK CONTENTS <br /> TANK USE 439 PETROLEUM TYPE 440 <br /> X 1. MOTOR VEHICLE FUEL F 1a. REGULAR UNLEADED IF 2. LEADED F 5. JET FUEL <br /> (If marked,complete Petroleum Type) X tb. PREMIUM UNLEADED IF 3. DIESEL 11' 6. AVIATION FUEL <br /> F 2. NON-FUEL PETROLEUM j 1c. MIDGRADE UNLEADED F 4. GASOHOL F 99. OTHER <br /> F 3. CHEMICAL PRODUCT <br /> F 4. HAZARDOUS WASTE(Includes COMMON NAME(from Hazardous Materials Inventory page)441 CAS#(from Hazardous Materials Inventory page) 442 <br /> Used Oil) <br /> r 95. UNKNOWN <br /> III.TANK CONSTRUCTION <br /> TYPE OF TANK F 1. SINGLE WALL F 3. SINGLE WALL WITH F 5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br /> (Check one item only) X 2. DOUBLE WALL EXTERIOR MEMBRANE LINER F 95. UNKNOWN <br /> F 4. SINGLE WALL IN A VAULT <br /> F 99. OTHER <br /> TANK MATERIAL-primary tank F 1. BARE STEEL X 3. FIBERGLASS/PLASTIC I 5, CONCRETE I'95. UNKNOWN 444 <br /> (Check one item only) I 2. STAINLESS STEEL 14. STEEL CLAD W/FIBERGLASS 18. FRP COMPATIBLE W/100%METHANOL 199. OTHER <br /> REINFORCED PLASTIC(FRP) <br /> TANK MATERIAL-secondary F 1. BARE STEEL X 3. FIBERGLASS/PLASTIC I' 8. FRP COMPATIBLE W/100%METHANOL F 95. UNKNOWN 445 <br /> tank <br /> F 2. STAINLESS STEEL F 4. STEEL CLAD W/FIBERGLASS I 9. FRP NON-CORRODIBLE JACKET F 99. OTHER <br /> (Check one item only) REINFORCED PLASTIC(FRP) F 10. COATED STEEL <br /> h 5. CONCRETE <br /> TANK INTERIOR LINING F 1. RUBBER LINED I� 3. EPDXY LINING F 5. GLASS LINING F95. UNKNOWN446 DATE INSTALLED 447 <br /> OR COATING <br /> F 2. ALKYD LINING F 4. PHENOLIC LINING X 6. UNLINED F 99. OTHER <br /> (Check one item only) (For local use only) <br /> OTHER CORROSION I' 1. MANUFACTURED X 3. FIBERGLASS REINFORCED PLASTIC r"95. UNKNOWN 448 DATE INSTALLED 449 <br /> PROTECTION IF APPLICABLE <br /> CATHODIC I' 4. IMPRESSED CURRENT F99. OTHER <br /> (Check one item only) PROTECTION (For local use only) <br /> F 2. SACRIFICIAL ANODE <br /> SPILL AND OVERFILL YEAR INSTALLED TYPE(For local use only)451 OVERFILL PROTECTION EQUIPMENT:YEAR INSTALLED 452 <br /> 450 <br /> (Check all that apply) X1. SPILL CONTAINMENT 1996 X 1. ALARM 1998 X 3. FILL TUBE SHUT OFF VALVE 1996 <br /> X2. DROP TUBE 1996 F 2. BALL FLOAT I 4. EXEMPT <br /> X 3. STRIKER PLATE 1996 <br /> IV. TANK LEAK DETECTION (A description of the monitoring program shall be submitted to the/oval agency.) <br /> IF SINGLE WALL TANK(Check all that apply): 453 IF DOUBLE WALL TANK OR TANK WITH BLADDER(Check one item only): 454 <br /> I 1, VISUAL(EXPOSED PORTION ONLY) F 5. MANUAL TANK GAUGING(MTG) F 1. VISUAL(SINGLE WALL IN VAULT ONLY) <br /> F 2. AUTOMATIC TANK GAUGING(ATG) F 6. VADOSE ZONE X2. CONTINUOUS INTERSTITIAL MONITORING <br /> F 3. CONTINUOUS ATG F 7. GROUNDWATER I 3. MANUAL MONITORING <br /> I� 4. STATISTICAL INVENTORY RECONCILIATION(SIR)+ F 8. TANK TESTING <br /> BIENNIAL TANK TESTING F 99. OTHER <br /> V.TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455 ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456 TANK FILLED WITH INERT MATERIAL? 457 <br /> gallons F Yes F No <br /> UPCF(1/99 revised) Formerly SWRCB Form B <br /> 6 <br />