Laserfiche WebLink
IFIED PROGRAM CONSOLIDATED FOR <br /> W TANKS <br /> UNDERGROUND STORAGE TANKS - TANK PAG <br /> VI.PIPING CONSTRUCTION(Check all that apply) <br /> UNDERGROUND PIPING I ABOVEGROUND PIPING <br /> SYSTEM TYPE X 1. PRESSURE F 2. SUCTION F 3. GRAVITY F 1, PRESSURE F 2. SUCTION F 3. GRAVITY 459 <br /> CONSTRUCTION F 1. SINGLE WALL F 3. LINED TRENCH r 99. OTHER r 1. SINGLE WALL F95. UNKNOWN 462 <br /> / X 2. DOUBLE WALL F95. UNKNOWN F 2. DOUBLE WALL F 99. OTHER <br /> MANUFACTURE <br /> R MANUFACTURER 461 MANUFACTURER 463 <br /> F 1.BARE STEEL F 6. FRP COMPATIBLE W/100%METHANOL F 1. BARE STEEL I 6. FRP COMPATIBLE W/100%METHANOL <br /> MATERIALS AND F 2. STAINLESS STEEL F 7. GALVANIZED STEEL F 2. STAINLESS STEEL IF 7. GALVANIZED STEEL <br /> CORROSION <br /> PROTECTION F 3. PLASTIC COMPATIBLE WITH CONTENTS F 95. UNKNOWN F 3. PLASTIC COMPATIBLE WITH CONTENTS F 8. FLEXIBLE(HDPE) I 99. OTHER <br /> X 4. FIBERGLASS F 8. FLEXIBLE(HDPE) r99. OTHER F 4. FIBERGLASS F 9. CATHODIC PROTECTION <br /> F 5. STEEL W/COATING F 9. CATHODIC PROTECTION 464 F 5. STEEL W/COATING F 95. UNKNOWN 465 <br /> VII.PIPING LEAK DETECTION(Check all that apply)(A description of the monitoring program shall be submitted to the kical agency) <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SINGLE WALL PIPING 466 SINGLE WALL PIPING 467 <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> F 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF FOR F 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF FOR LEAK <br /> LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND VISUAL SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND VISUAL ALARMS <br /> ALARMS F 2. MONTHLY 0.2 GPH TEST <br /> F 2. MONTHLY 0.2 GPH TEST <br /> I, 3. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> F 3. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> F 4. DAILY VISUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS: CONVENTIONAL SUCTION SYSTEMS(Check all that apply): <br /> F 5. DAILY VISUAL MONITORING OF PUMPING SYSTEM+TRIENNIAL PIPING INTEGRITY F 5. DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> TEST(0.1 GPH) F 6. TRIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): <br /> F 7. SELF MONITORING F 7. SELF MONITORING <br /> GRAVITY FLOW: GRAVITY FLOW(Check all that apply): <br /> F 9. BIENNIAL INTEGRITY TEST(0.1 GPH) F B. DAILY VISUAL MONITORING <br /> F 9. BIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SECONDARILY CONTAINED PIPING SECONDARILY CONTAINED PIPING <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND(check one) <br /> (Check one) - <br /> F a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS I a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> X b. AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM F b. AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM DISCONNECTION <br /> DISCONNECTION <br /> I c. NO AUTO PUMP SHUT OFF r c. NO AUTO PUMP SHUT OFF <br /> X 11. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITH FLOW SHUT OFF OR r 11. AUTOMATIC LEAK DETECTOR <br /> RESTRICTION 12. ANNUAL INTEGRITY TEST(0.1 GPH) F 12. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> SUCTION/GRAVITY SYSTEM: SUCTION/GRAVITY SYSTEM: <br /> IF 13. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS F 13. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS <br /> EMERGENCY GENERATORS ONLY(Check all that apply) EMERGENCY GENERATORS ONLY(Check all that apply) <br /> F 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF+AUDIBLE AND I� 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF+AUDIBLE AND VISUAL <br /> VISUAL ALARMS ALARMS <br /> F 15, AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITHOUT FLOW SHUT OFF OR I 15. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST) <br /> RESTRICTION <br /> I 16. ANNUAL INTEGRITY TEST(0.1 GPH) F 16. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> I 17. DAILY VISUAL CHECK F 17. DAILY VISUAL CHECK <br /> VIII.DISPENSER CONTAINMENT <br /> DISPENSER CONTAINMENT F 1. FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE F 4. DAILY VISUAL CHECK <br /> DATE INSTALLED 468 F 2. CONTINUOUS DISPENSER PAN SENSOR+AUDIBLE AND VISUAL ALARMS F 5. TRENCH LINER/MONITORING <br /> 1998 X 3. CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR DISPENSER+AUDIBLE AND VISUAL ALARMS F 6. NONE 469 <br /> IX 0WNFRlQIPFRATQRqIrNATIjRF <br /> I certify that the information provided herein is true and accurate to the best of my knowledge. <br /> SIGNAT E�WN �ER/OPE � Z� DATE 470 <br /> Z�z <br /> 4/27/02 <br /> NAME OF OWNER/OPERATOR(print) 471 TITLE OF OWNER/OPERATOR 472 <br /> Bruce T. Marubashi for Shell Oil Products US H,S&E Analyst 925-766-3498 <br /> Permit Number(Forlocal use only) 473 I Permit Approved(For local use only) 474 I Permit Expiration Date(For local use only) 475 <br /> 6 <br />