Laserfiche WebLink
AML Akik <br /> NW <br /> San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax: (209) 468-3433 Web:www.sjgov.org/ehd <br /> Facility Name: Facility Address: Date: <br /> RIPON SHELL" 341 E MAIN ST, RIPON January 30, 2017 <br /> 's€ .>atu <br /> ,IS ttt"I3-3tv "rt.,. z�_.�s.?, .,. <br /> 322 HSC 25281.6(a) Unburied below grade emergency generator system failed to meet exemption status ❑V ❑R ❑COS <br /> 323 HSC 25283.5(a) Unburied below grade UST system failed to meet exemption status ❑V ❑R ❑COS <br /> 324 CCR 2717.1(g) Tampered with red tag ❑V ❑R ❑COS <br /> 325 CCR 2717.1(f) Deposited petroleum into a red tagged UST ❑V ❑R ❑COS <br /> 326 HSC 25299(a)(9) Tampered with or disabled leak detection devices or alarms ❑V ❑R ❑COS <br /> 327 CCR 2631.1 UST system not compatible with the substance stored ❑V ❑R ❑COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements ❑V ❑R ❑COS <br /> 329 HSC 25298 Failed to comply with permanent closure requirements ❑V ❑R ❑COS <br /> 330 CCR 2636(f)(6) Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system ❑V ❑R ❑COS <br /> mw,vi ;, <br /> h <br /> NO <br /> W1111A PUMP <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve ❑V ❑R Li COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed ❑V ❑R ii COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) ❑V ❑R ❑COS <br /> 404 j CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) p q ❑V ❑R g❑COS <br /> _ >�`i 4$k'}}`" <br /> a <br /> h <br /> 2010 See below Unlisted Administration/Documentation violation ❑V ❑R ❑COS <br /> 2030 See below Unlisted Operations/Maintenance violation ❑V ❑R ❑COS <br /> 2060 See below Unlisted Design/Construction violation ❑V ❑R ❑COS <br /> VON <br /> "�I��-. - <br /> .......... <br /> Item# Remarks <br /> 105 CCR 2632(d)(1) Failed to have an approved UST monitoring plan. <br /> The monitoring plan is not current and/or not approved by the EHD. The uploaded monitoring plan (uploaded on <br /> 12-23-16)for both tanks indicates that the installed#321 sensors inside all dispensers trigger"Automatic Pump <br /> Shutdown"when sensors are in alarm. Based on onsite observations these are stand alone sensors which trigger <br /> dispenser shut downs only (pump shut downs are not triggered).The monitoring plan must be uploaded to the <br /> California Environmental Reporting System (CERS). Immediately log into CERS, make the necessary changes, <br /> and submit for review by the EHD. <br /> This is a Class II violation. <br /> 204 CCR 2712(i) Current monitoring plan approved by the EHD not found on site. <br /> An approved copy of the monitoring plans were not available for inspection. A copy of these plans shall be <br /> accessible on site at all times. Immediately locate and retain a copy on site. Submit proof of correction to the EHD. <br /> This is a repeat violation, Class ll. <br /> FA0003753 PR0231477 SCO01 01/30/2017 <br /> EHD 23-01 Rev.09/22/16 Page 3 Of 4 Underground Storage Tank Program OIR <br />