Laserfiche WebLink
San Joaquin County A ENDED <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax:(209)468-3433 Web:www.sjgov.org/ehd <br /> M �I► Ic� r �; earl X111$ ± � <br /> Facility Name: Facility Address: !T30, 2017 <br /> RIPON SHELL* 341 E MAIN ST, RIPON <br /> � 00LAT S <br /> sy.. p. 4 ws yaco <br /> mom <br /> Item# Remarks <br /> 205 CCR 2712(i) Failure to have an approved UST response plan available onsite. <br /> No response plan was available onsite at the time of inspection. The response plan must be uploaded to the <br /> California Environmental Reporting System (CERS) and available onsite. Immediately locate and retain a copy <br /> onsite. Ensure a copy is available for inspection at any time. Submit proof of correction to the EHD. <br /> This is a repeat violation, Class Il. <br /> 306 CCR 2630(d) Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity. <br /> The UDC 1/2 sensor was leaning at an angle greater than 45 degrees and not installed at the lowest point of the <br /> sump (at the designated depression inside the sump) and not located to detect a leak at the earliest opportunity. <br /> Monitoring equipment shall be maintained to be able to detect a leak at the earliest possible opportunity. The <br /> sensor was relocated to the lowest point of the sump by the service technician. Ensure that all monitoring <br /> equipment is maintained to detect a leak at the earliest opportunity. <br /> This is a Class 11 violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by 3-2-17. <br /> Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br /> documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br /> Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer (if <br /> applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br /> Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br /> AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING <br /> THIS FACILITY BACK INTO COMPLIANCE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received by: Date: Inspector: Inspector Phone: <br /> va QUA ELENA MANZO, Senior REHS 209 <br /> 1 Printed Name and Title: ( ) 953-7699 <br /> MO <br /> U\ <br /> PR0231477 SCO01 01/30/2017 <br /> EHD 23-01 Rev.09/22/16 Page 4 of 4 Underground Storage Tank Program OIR <br />