My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
341
>
2300 - Underground Storage Tank Program
>
PR0231477
>
COMPLIANCE INFO_2006-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/13/2023 4:34:13 PM
Creation date
6/3/2020 9:50:04 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2018
RECORD_ID
PR0231477
PE
2361
FACILITY_ID
FA0003753
FACILITY_NAME
RIPON SHELL*
STREET_NUMBER
341
Direction
E
STREET_NAME
MAIN
STREET_TYPE
ST
City
RIPON
Zip
95366
APN
26114007
CURRENT_STATUS
01
SITE_LOCATION
341 E MAIN ST
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231477_341 E MAIN_2006-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
548
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
-8 9 <br />- <br />Veeder-Root ISD System Specifications <br />TLS Console & ISD Software Version Number <br />The ISD audible alarm shall be installed at a location that is most likely to be occupied by the <br />station attendant during normal station operation (e.g. cash register) to hear the alarm. The <br />TLS console shall be installed in a location that allows the RS232 port to be easily accessible, <br />and if applicable, per district requirements, for use at anytime. A vacant RS232 serial port shall <br />always be available to electronically download reports. <br />The presence of ISD and the ISD software version number can be verified on the TLS Console <br />LCD screen by using the <STEP> key or by using the TLS Console <PRINT> key to print and <br />review the latest ISD Daily Report. See Figures 213-4 and 213-5 for TLS and ISD verification <br />instructions. <br />The TLS Console must have a printer as well as an RS232 interface port. <br />If the TLS is equipped with security features which prohibit access to the TLS, instructions to <br />override these security features shall be maintained on site in accordance with air district <br />requirements and shall be available to the air district upon request. <br />Operability Test Procedure <br />The Veeder-Root ISD operability test procedure provided in Exhibit 10 and Exhibit 17, and in <br />section 12 of the ARB Approved Installation, Operation and Maintenance Manual (IOM), <br />shall be used at GDF sites to determine the operability of the Veeder-Root ISD system to <br />comply with applicable performance standards and performance specification in CP -201. <br />Testing the ISD equipment in accordance with this procedure will verify the proper selection, <br />setup and operation of the TLS Console sensors and interface modules. <br />The Vapor Flow Meter <br />The Veeder-Root ISD system requires one Vapor Flow Meter per dispenser installed in <br />accordance with Section 15 of ARB Approved IOM (Veeder-Root ISD Balance Vapor Flow <br />Meter Manual Installation Guide (577013-916, Rev. B)) for the Veeder-Root ISD System. <br />The Vapor Flow Meter is an intrinsically safe sensor that is wired to the TLS Console Smart <br />Sensor Module via a conduit dedicated to TLS Console low -voltage sensors. Figure 213-6 <br />shows the ISD Vapor Flow Meter. Figures 213-10 and 213-11 show the installation <br />configuration. <br />The Vapor Pressure Sensor <br />The Veeder-Root ISD system requires one Vapor Pressure Sensor per GDF installed into one <br />of the dispensers located closest to the tanks (If a row of dispensers are equal distance from the <br />tank pad and within 10' of each other, any dispenser can be used) in accordance with Section <br />13 of the ARB Approved IOM Manual. For vapor vent stack installation, determine which <br />vapor vent stack line is closest to the tank being monitored. Select this line for the addition of <br />the pressure sensor. The connection must be BELOW the Veeder-Root Carbon Canister if <br />equipped in accordance with Section 13 of the ARB Approved IOM Manual. Caution: <br />Installation of the pressure sensor on the vapor vent stack is only allowed at facilities equipped <br />with a Veeder-Root Vapor Polisher or Franklin Fueling/Healy Clean Air Separator. The Vapor <br />Pressure Sensor is an intrinsically safe sensor that is wired to the TLS Console Smart Sensor <br />VST Phase 11 EVR System Including Veeder-Root ISD, Exhibit 2 - VR -204-H <br />