My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1999-2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1097
>
2300 - Underground Storage Tank Program
>
PR0231497
>
COMPLIANCE INFO_1999-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/23/2024 2:11:22 PM
Creation date
6/3/2020 9:50:06 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1999-2009
RECORD_ID
PR0231497
PE
2361
FACILITY_ID
FA0000279
FACILITY_NAME
ESCALON MINI MART
STREET_NUMBER
1097
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
ESCALON
Zip
95320
APN
22510001
CURRENT_STATUS
01
SITE_LOCATION
1097 YOSEMITE AVE
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231497_1097 YOSEMITE_1999-2009.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
338
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Jan. 19. 2009 1 : 09PM West Star Environmental, Inc. No- 7703 P. 3/7 <br /> u n rs�U,i nuua:y /-vv/- Page 2 of <br /> 4. TANK ANNULAR TESTING <br /> Test Method]Developed By: Tank Manufacturer Ina Standard Professional Engineer <br /> Otber(Specify) CS B <br /> Test Method Used: Pressure Vacuum Hydrostatic <br /> other(Specify) X <br /> Test Equipment Used! INCON STS Equipment Resolution: _002 <br /> Tank# Tank # Tank# Tank# <br /> Is Tank Exempt From Testing? Yes Yes No Yes No Yes No <br /> Tank Capacity: 13,000/7,000 <br /> Tank Material: FEBERGLASS <br /> Tank Manufacturer: J00R. <br /> Product Stored: GASOLENE <br /> Wait time between applying <br /> pr uum/water and <br /> starting test: 20N41N <br /> Test Start Time: 10:00am <br /> initial Reading(Rl): 10VAC <br /> Test End Time: 11.00 <br /> Final Reading(RF): IOVAC <br /> Test Duration: IHR <br /> Change in Reading(RF-RI): OVAC <br /> Pass/Fail Threshold or Criteria: NONE NONE NONE NONE <br /> Test Result: (-Pass-) Fal! Pass Fall Pass Fail paw Fall <br /> Was sensor removed for testing? No A FYes o N/A Yes o N/A Yes o N/A <br /> Was sensor replaced an <br /> verified functional No N/A testing? Yes No N/A Yes No N/A Yes No N/A <br /> Comments-(include information on repairs made prior io testing, and recommended follow-up for failed tests) <br /> Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br /> containment,such as systems that are hydrostatically monitored or under constant vacuum,are exempt from periodic containment <br /> testing.-California Code of Regulations,Title 23,Section 2637(ax6)) <br />
The URL can be used to link to this page
Your browser does not support the video tag.