My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1999-2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1097
>
2300 - Underground Storage Tank Program
>
PR0231497
>
COMPLIANCE INFO_1999-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/23/2024 2:11:22 PM
Creation date
6/3/2020 9:50:06 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1999-2009
RECORD_ID
PR0231497
PE
2361
FACILITY_ID
FA0000279
FACILITY_NAME
ESCALON MINI MART
STREET_NUMBER
1097
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
ESCALON
Zip
95320
APN
22510001
CURRENT_STATUS
01
SITE_LOCATION
1097 YOSEMITE AVE
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231497_1097 YOSEMITE_1999-2009.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
338
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Jan. 19. 2009 1 :09PM West Star Environmental, Inc. No. 7703 P. 5/7 <br /> Page 4 of <br /> SWRCA January 2002 is <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By. SUMP Manufacturer industry Standard Professional Engnteer <br /> Other(SpeCify) CSWRB <br /> Test Method Used: Pressure Vacuum Hydrostatic <br /> Other(Specify) x <br /> Test Equipment Used:'N N STS Equipment Resolution: 002 <br /> Samp# 87STFSUAe Snmp#91 STP SiIMP Snmp # Sump # <br /> Sump Diameter: 48IN 48rN <br /> Sump Depth: 5FT 5FT <br /> Sump Material: FIBERGLASS FIBERCTLASS <br /> Height na Tank Top to Top o <br /> Highest Piping Penetration: 4FT .4FT <br /> Height from Tank.Top to Lowest <br /> Electrical Penetration: 1FT IFT <br /> Condition of sump prior to testing: CLEAN CLEAN <br /> Portion of Sump Tested' 75% 75% <br /> Does nae shut down w en <br /> sump sensor detects liquid(both Yes No NIA E0No NIA Yes No N/A <br /> product and water)?* Yes Na N/A <br /> Turbine shutdownresponse time INSTANT INSTANT <br /> Is system pro-M= r <br /> shutdown?* Yes No NIA Yes No NIA Yes No N/A Yes No WA <br /> Was fail-safe vert ed to be <br /> operational?' Yes No N/A Yes No N/A Yes No N/A Yes No N/A <br /> Wait time between app <br /> pressure/vacuum/water and starting <br /> test 20N9N 20NGN <br /> Test Start Time: 11:00 12:30 <br /> Initial Reading(111): 1 0.000 <br /> Test End Time: 11:30 1:00 <br /> Final Reading(RF): 1.9598 0.000 <br /> Test Duration: 30MIN 30MIN <br /> Change in Reading(RF-Rl): -0.001 0.000 <br /> Pass/Fail Threshold or Criteria: /.0.002 +/-0.002 <br /> Test Result; f'gSr Ar <br /> Was sensor removed for testing? es No N/A Yes No N/A Yes No N/A Yes No N/A <br /> Was sensor properly replaced and ^' <br /> verged functional after testing? Yes No N/A Yes No NIA Yes No N/A Yes No NIA <br /> Comments- (include information on repairs made prior to testing, and recommended follow-up forfailed tests) <br /> i If the entire depth of the sump is not tested,specify how much was tested.If the answer to pof the questions indicated with an <br /> asterisk(_)is'NO"or"NA",the entire sump must be tested.(See S W RCB LG-160) <br />
The URL can be used to link to this page