My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1999-2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1097
>
2300 - Underground Storage Tank Program
>
PR0231497
>
COMPLIANCE INFO_1999-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/23/2024 2:11:22 PM
Creation date
6/3/2020 9:50:06 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1999-2009
RECORD_ID
PR0231497
PE
2361
FACILITY_ID
FA0000279
FACILITY_NAME
ESCALON MINI MART
STREET_NUMBER
1097
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
ESCALON
Zip
95320
APN
22510001
CURRENT_STATUS
01
SITE_LOCATION
1097 YOSEMITE AVE
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231497_1097 YOSEMITE_1999-2009.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
338
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Aug. 4. 2008 12:48 PM" West Star Environmental, Inc. No, 0125 P. 3 <br /> Software Version Installed: <br /> Complete the following checklist: <br /> Yes pN® is t eau ble alarm operational? <br /> ® yesUROT s Me—visual alarm operational'! <br /> Yes El No* ere all sensors visually inspected, notion y tested,and co irmc o crationa <br /> Yes ❑ No*- ere all sensors instaa at Qwest point of secondary containment and positioned so that other equipment w <br /> not interfere with their proper operation? <br /> I a arms are relayed to a remote monitoring station, is all communications equipment(e.g.modeu <br /> Yes ❑Noe operational? <br /> NO* For pressurized piping systems,does the turbine automatically shut awn secondary contain <br /> the piping seconcontainme <br /> Yes monitoring system detects a leak, fails tooperate,or is electrically disconnected?if es:which sensors initia <br /> N/A positive shut-down?(Check all that apply) 0 Sump/Trench Sensors; ®Dispenser Containment Sensors. <br /> Did Zou confirm positive shut-down due to leaks and sensor failure/disconnection? MYeS; ❑No. <br /> No* For tanks that utilize the system as the tank overfill warming device(i.e.no mechanical overfill prevention valve <br /> [] iuswlled) is The overfill warming alarm visible and audible at the tank fill point(s)and operating properly?If so,at <br /> Yes N/A <br /> what percent of tank capacity does the alarm et? % <br /> Ycs* No* Was any monitoring equipment broken?if yes,identify specific sensors,probes,or other equipment replaced and <br /> list the manufacturer name and model for all Lvplacernent parts in Section E below. <br /> Yes* tog Qui oun insi a any secon ary containment systems esign as dry systems. ec a that apply) <br /> Product, ❑QVater.if cs,descrihe causes in Section E below. <br /> _ IN Yes No` Was mouitortng system set-up reviewed to ensure proper settings?Attach set up reports,if app c e <br /> M3 Yes No* Is all monitoring equipment opeiRional per manufacturers specifications? <br /> ffi In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: Water found in both STP sumps,removed water. Sensor in PREMIUM STP sump inop replaced and verified by <br /> inspector. <br /> Page 2 of 4 03/01 <br />
The URL can be used to link to this page
Your browser does not support the video tag.