COMPLIANCE INFO_1999-2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1097
>
2300 - Underground Storage Tank Program
>
PR0231497
>
COMPLIANCE INFO_1999-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/23/2024 2:11:22 PM
Creation date
6/3/2020 9:50:06 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1999-2009
RECORD_ID
PR0231497
PE
2361
FACILITY_ID
FA0000279
FACILITY_NAME
ESCALON MINI MART
STREET_NUMBER
1097
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
ESCALON
Zip
95320
APN
22510001
CURRENT_STATUS
01
SITE_LOCATION
1097 YOSEMITE AVE
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231497_1097 YOSEMITE_1999-2009.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
338
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
`Jan. 23. 2006` 1 :20PM°&'" W A Star E n v i ronmenta1, Inc, No, 6876 P. 3 <br /> Software Version Installed: 30A <br /> Coot lete the folio eke ' t: <br /> ® Yes ® No* Is-the au a Marmoperational? <br /> ® Yes ❑ Noy 15 ffie Viso a1Mo ratZo <br /> ® Yes ❑ No* Were au sensors visually inspecK fEmMoniffllf6i4 and con rmed o fort <br /> ® Yes o Were all sensors installed at lowest point of secondary containment and positioned so that other equipment v% <br /> not interfere with their pLoE operation? <br /> ❑ Yes ® No* If alarms are relayed to a remote monitoring station,is all communications equipment(e.g.modem <br /> N/A operational? <br /> ® Yes ® o For pressurized piping systems,does the tpr ine automatically shut down if the piping secondary containnve s <br /> * N/A monitoring system detects a leak,fails to operate,or is electrically disconnected. If es:which sensors init�at <br /> positive shut-down?(Check all that?ply) H Sump/Trench Sensors; 19 Dispenser Containment Sensors. <br /> Did you confirm positive shut-down due to leaks aqLsensor failureidisconnection? ®Yes; ❑No. <br /> ❑ Yes El No* For tank systems that utilize the monitorig stem as the p ' overfill device(i.e. <br /> ® N/A mechanical overfill prevention valve is installed,is the overfill warning visible and audible at the tm <br /> fill . s and o ral:W 2 so,at what percent of tank capacity the alarm tri er? <br /> ® Yes* ❑ No Was any monitoring equipment rep ac ?I yes,t entt specs c sensors,pro es,or other equipment rep a�, <br /> and list the manufacturer name and model for all replacement arts in Section below. <br /> ® Yes* ® No Was liquidoun mss a any seeon ary containment systems designed as ry systems. ec a t t aPPYI <br /> Product: ❑Water.If yes,describe causes in Section F,below. <br /> Yes O o as momtonrt qSteM set- reviewed to ensure proper settin ?Attach set u rts if yZlicable <br /> Yes ❑ is o all m*nitoring equirgent operational M manufacturer's s tfieations? <br /> * to Section E br ow, Ascribe how and when these deficiencies were or will be corrected. <br /> E. COBlMent:S;Tbe 9) turbine sump sensor failed,installed a new BBW LS-3A sensor.yards LS-3A SN WSE0622017 <br /> Tested ok. <br /> Page 2 of 4 03101 <br />