My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2014
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1097
>
2300 - Underground Storage Tank Program
>
PR0231497
>
COMPLIANCE INFO_2010-2014
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/23/2024 3:25:18 PM
Creation date
6/3/2020 9:50:12 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2014
RECORD_ID
PR0231497
PE
2361
FACILITY_ID
FA0000279
FACILITY_NAME
ESCALON MINI MART
STREET_NUMBER
1097
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
ESCALON
Zip
95320
APN
22510001
CURRENT_STATUS
01
SITE_LOCATION
1097 YOSEMITE AVE
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231497_1097 YOSEMITE_2010-2014.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
487
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
t <br /> SWRCB,January 2002 Page Z. of? <br /> 4. TANK ANNULAR TESTING <br /> Test Method Developed By: 0 Tank Manufacturer AIndustry Standard ❑Professional Engineer <br /> ❑Other(Spec) <br /> Test Method Used: ❑Pressure Z Vacuum ❑Hydrostatic <br /> 0 Other(Specify) <br /> OTestuipmentUsed: _ p" %f L, Equipment Resolution: <br /> Tank# ` Tank# Tank# Tank# <br /> Exempt From Testing?' 0 Yes KNo ❑Yes ❑No 0 Yes ❑No 0 Yes ❑No <br /> Tank Capacity: <br /> Tank Material: 5 <br /> Tank Manufacturer: , <br /> Product Stored: <br /> Wait time between applying <br /> pressure/vacuum/water and <br /> starting test: <br /> Test Start Time: <br /> Initial Reading(RI): � <br /> Test End Time: <br /> Final Reading l(�pF): ` <br /> 1e <br /> Test Duration: <br /> Change in Reading(RF-RI): <br /> Pass/Fail Threshold or Criteria: ®r)IC PCA,y5 <br /> .Test�2eglt F.:' ' ' fP. .i. x Fads Q Fail mO bass j❑fall ❑�PaS� CI fall �7 Piss: Q Sil <br /> Was sensor removed for testing? ,X Yes ❑No 0 NA Cl Yes ❑No [INA ❑Yes ❑No 0 NA ❑Yes 0 No 0 NA <br /> Was sensor properly replaced and verified functional after testin ? yes 0 No 0 NA 0 Yes 0 No 0 NA 0 Yes 0 No ❑NA ❑Yes 0 No 0 NA <br /> i <br /> C0MMents—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> i <br /> i <br /> i <br /> iI <br /> I <br /> 1 Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br /> containment,such as systems that are hydrostatically monitored or under constant vacuum,are exempt from periodic containment <br /> testing. {California Code of Regulations,Title 23,Section 2637(a)(6)) <br />
The URL can be used to link to this page
Your browser does not support the video tag.