My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2014
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1097
>
2300 - Underground Storage Tank Program
>
PR0231497
>
COMPLIANCE INFO_2010-2014
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/23/2024 3:25:18 PM
Creation date
6/3/2020 9:50:12 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2014
RECORD_ID
PR0231497
PE
2361
FACILITY_ID
FA0000279
FACILITY_NAME
ESCALON MINI MART
STREET_NUMBER
1097
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
ESCALON
Zip
95320
APN
22510001
CURRENT_STATUS
01
SITE_LOCATION
1097 YOSEMITE AVE
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231497_1097 YOSEMITE_2010-2014.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
487
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 t Page of <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By: 0 Sump Manufacturer Industry Standar ❑Professional Engineer <br /> ❑Other(Spec) <br /> Test Method Used: 0 Pressure ❑vacuum )Hydrostatic <br /> 0 Other(Spec) ` <br /> Test Equipment Used: V"C 75 .S Equipment Resolution: <br /> Sump# Sump# / Sump# Sump# ` <br /> Sump Diameter: _ t <br /> Sump Depth: <br /> Sump Material: <br /> Height from Tank Top to Top of l l P r <br /> Hi hest Pi in Penetration: `7 <br /> I -Height from Tank Top to Lowest , <br /> Electrical Penetration: b' <br /> Condition of sump prior to testing: n &sr ` <br /> Portion of Sump Tested' kP- Aa <br /> Does turbine shut down when <br /> sump sensor detects liquid(both ❑Yes 0 No R(NA 0 Yes 0 No ,&NA D.Yes ,ONO DNA'. ❑Yes ONO ❑NA <br /> product and water)?* <br /> Turbine shutdown response time <br /> Is system programmed for fail-safe <br /> shutdown? ❑'Yes 0 No )4 NA ❑Yes 0 No �NA ❑Yes 0 No DNA ❑Yes ❑No ❑NA <br /> Was fail-safe verified to be ❑Yes ❑No XNA 0 Yes ❑No @SNA 0 Yes 0 No ❑NA ❑Yes ONO ❑NA <br /> operational?` <br /> Wait time between applying <br /> pressure/vacuum/water and starting IS r►'► ' '1 I w, A <br /> test: <br /> Test Start Time: Z 0 z `) <br /> Initial Reading(RI): <br /> Test End Time: ; <br /> Final Reading(RF) <br /> r <br /> Test Duration: " ;:, e►1 : +n <br /> Change in Reading(RF-RI): boo r <br /> Pass/Fail Threshold or Criteria: 2— <br /> `T�st�`Resu��'t�����"X'�.�:� <br /> Was sensor removed for testing? ASYes ❑No ❑NA Yes 0 No ❑NA ❑Yes ❑No 0 NA ❑Yes 0 No DNA <br /> Was sensor pl operly replaced and , Yes ❑No ❑NA Yes 0 No ❑NA 0 Yes ❑No 0 NA ❑Yes ❑No ❑NA <br /> verified functional after testing? <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> 14P <br /> If the entire depth.of the sump is not tested,specify how much was tested. If the answer to my of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire sump must be tested. (See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.