My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2014
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1097
>
2300 - Underground Storage Tank Program
>
PR0231497
>
COMPLIANCE INFO_2010-2014
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/23/2024 3:25:18 PM
Creation date
6/3/2020 9:50:12 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2014
RECORD_ID
PR0231497
PE
2361
FACILITY_ID
FA0000279
FACILITY_NAME
ESCALON MINI MART
STREET_NUMBER
1097
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
ESCALON
Zip
95320
APN
22510001
CURRENT_STATUS
01
SITE_LOCATION
1097 YOSEMITE AVE
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231497_1097 YOSEMITE_2010-2014.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
487
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Overview *TSP-K12 Riser ap for 2-inch riser pipes, includes a <br /> The TSP-ULS is a Standard sensor that is used to detect pre-installed 1/2 inch NPT compression gland (cord grip) <br /> the presence of a liquid in the normally dry Class 1, Division fitting. Other riser caps are available for different riser <br /> 1, Group D Hazardous Areas of: sumps, dispenser-pans, pipe sizes—consult your factory rep. <br /> and interstitial areas of double-wall steel storage tanks. * Riser pipe—2 inch diameter(OD), threaded at one end <br /> The sensor is supplied with electrical connectors, 25 feet of (NPT-14)with all rough edges removed/deburred from <br /> cable, and a cord-grip fitting (see diagrams).The TSP-ULS the inner edges. <br /> uses magnetic-float/reed-switch technology (the sensor *= Needed for installation in UST interstitial areas (Figure 2) <br /> must be suspended vertically (See Figure 1) so the float <br /> can rise freely with the level of a liquid). Installation Sequence <br /> When the float rises more than 1/2 of an inch, the 1. Install Riser Pipe, Manhole. <br /> magnetically sensitive reed switch will open (see internal 2. Install conduit, EYS fittings, and weatherproof <br /> float in Figure 1).An open circuit is recognized as an alarm- junction box. <br /> condition at the intrinsically safe (I.S) leak detection circuits 3. Shut off power. <br /> of the FFS (Franklin Fueling Systems)ATG console. ELECTRICAL DANGER Avoid electrical <br /> wnt) shock hazards: ensure all power <br /> Colored <br /> (alk going to the ATG console is turned off, <br /> pen tape�� ) <br /> tagged, and locked-out at the power <br /> panel before doing any maintenance or <br /> Install Height= <br /> Measured height For installation in double-walled steel tanks,the installation work at the ATG console. <br /> +1.5 inch(38.1 mm install height is measured from the top of the riser <br /> allowance for to the bottom of the interstitial space in the tank 4. Interstitial installation—see Figure 1 & 2, measure <br /> TSP-K12 height the INSTALL HEIGHT needed and add 1.5 inches <br /> Typical Sensor Input = total height. Mark the total height on the sensor <br /> Interface(Channel N): cable as shown in Figure 1, pull the cable through <br /> 3.62 (wht In the TSP-K12 Riser Cap and cord-grip until the mark <br /> (92 mm) c Ncshows at the top of the cord grip fitting. Tighten the <br /> (B Grid <br /> fitting and lower the sensor into the interstitial area <br /> of the tank as shown in Figure 2. <br /> Magnetic <br /> 0.52 <br /> Reed float switch <br /> (13.2 mm) opens when floatCoer for TSP-K12 riser cap <br /> moves up 0.52 inch 14 inch(35.56 cm) (with cord grip-compression fitting) <br /> (13.2 mm) O Min.dia.manhole <br /> —1.48 Suspend Sensor Veritcally a 9 ID ,=ti—Concrete slab <br /> (37.6 mm) Manhole per NFPA 30 <br /> Figure 1: TSP-ULS Dimensions Clean fill material <br /> (Gravel typical) /'" <br /> Materials Required weatherproof/ <br /> Junction box <br /> Compression <br /> • Optional—TSP-DB1 Epoxy Seal kit for no-strip electrical fitting(Cord grip) <br /> connectors—recommended for sites: within flood zones, <br /> Install height Eys seal Fitting <br /> high groundwater tables, with poor drainage, or when as measured) <br /> junction boxes are not used. 1/2 or 3/4 inch conduit <br /> • 1/2 or 3/4 inch NPT(National Pipe Thread, tapered), <br /> Rigid Metal Conduit(RMC)or nonmetallic(PVC)conduit Double-wall 2i"c` "ser pipe <br /> if allowed by local codes. steel tank Interstitial area(dry) <br /> • EYS Seal fittings and Epoxy to fill the fitting after TSP-ULS <br /> operational testing is completed. sensor <br /> • Weatherproof junction Box, gasket, and cover, plus a <br /> 3/4 to 1/2 inch NPT reducing bushing if 1/2 inch RMC is <br /> used —see the ATG Installation Guide for recommended Figure 2:Installation in Double-walled Steel Tanks <br /> electrical Junction Boxes. <br /> • Wire: THHN, TFFN or THWN, 18 AWG, White & Black, 5. Pull the sensor cable through the cord grip fitting at <br /> or Alpha Cable#58411, 0.114 0.D. — 1,500 feet(457 the junction box (also see Figure 3 for installation <br /> meters) max. length.Alpha cable#58411 must be use within a sump) and tighten all remaining cord-grip <br /> with nonmettalic conduit. fittings. Trim wire/cables to a 6 or 8 inch (15 or <br /> • Slip joint pliers to seat the no-strip, self-sealing wire 20 cm) service-loop, and splice the sensor and <br /> console cable/wires together as shown in Figure 4. <br /> connectors—connectors are supplied with the sensor. <br /> • UL Classified Thread Sealant or pipe dope. <br /> 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.