My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2014
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1097
>
2300 - Underground Storage Tank Program
>
PR0231497
>
COMPLIANCE INFO_2010-2014
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/23/2024 3:25:18 PM
Creation date
6/3/2020 9:50:12 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2014
RECORD_ID
PR0231497
PE
2361
FACILITY_ID
FA0000279
FACILITY_NAME
ESCALON MINI MART
STREET_NUMBER
1097
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
ESCALON
Zip
95320
APN
22510001
CURRENT_STATUS
01
SITE_LOCATION
1097 YOSEMITE AVE
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231497_1097 YOSEMITE_2010-2014.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
487
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 0 <br /> SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov.org/ehd <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT CONTINUED <br /> Facility Facility Inspection <br /> Name: Escalon Mini Mart Address: 1097 Yosemite Ave, Escalon, CA Date: Jan 9, 2014 <br /> VIOLATIONS <br /> # C1 C2 M Code Section HSC=CA Health and Safe Code;CFR=Code of Federal Regulations <br /> C1=Class 1 violation;C2=Class 2 violation;M=Minor violation <br /> Non-Pressurized Piping(continued) <br /> 702 CCR 2643(e) Biennial tightness test of gravity piping not performed(pre-January 1,1984) (M7) <br /> 703 CCR 2643(d) Triennial line test for conventional suction piping not performed(pre-January 1,1984) (M1) <br /> Other Violations <br /> 999 1 10ther: See attached"Continuation—Official Inspection Report"for violation(s)not listed above. <br /> SUMMARY OF VIOLATIONS <br /> CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Onsite to conduct a routine UST inspection and observe monitoring system certification conducted <br /> today. <br /> Class II Violations: 104, 108; 109, 110', 111', 113, 303; 305; 307-1 308)2_0q <br /> 104. Financial responsibility documents have not been submitted to the EHD. Current financial <br /> responsibility documents are required to be submitted annually. Updated financial responsibility <br /> documents were received at the time of inspection. CORRECTED. <br /> 109, 110, & 111. Annual monitoring system certification, leak detector testing, and spill container testing <br /> were last performed on December 27, 2012 and was completed on January 9, 2014 and is considered <br /> one month past due. These tests are required once every 12 months. Take all necessary precautions <br /> to ensure testing is performed in a timely manner. <br /> 113. Mr. Lyle Meeks performed several monthly designated operator inspections (February 2013 <br /> through November 2013) and a notification was not provided to the EHD within 30 days of the change. <br /> Any designated operator changes shall be reported to the EHD with 30 days. An updated notification <br /> identifying Lyle was submitted to the EHD at the time of inspection.identifying all the designated <br /> operators for this facility. CORRECTED. <br /> 204. The designated operator failed to check and note the correct (most current) test dates for the <br /> monitoring system certification on the January 2013 through April 2013 designated operator monthly <br /> inspection reports. During the monthly inspection, the designated operator shall check that all required <br /> testing and maintenance for the UST system have been completed and document the dates they were <br /> done. Ensure that designated operators performing monthly inspections at this facility are including all <br /> of the required information on the reports. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> InspectorReceived By: � Title: <br /> e Q 0&p,ti C4i' <br /> EHD 23-02 Rev 04/19112 Page 3 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.