My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2014
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1097
>
2300 - Underground Storage Tank Program
>
PR0231497
>
COMPLIANCE INFO_2010-2014
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/23/2024 3:25:18 PM
Creation date
6/3/2020 9:50:12 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2014
RECORD_ID
PR0231497
PE
2361
FACILITY_ID
FA0000279
FACILITY_NAME
ESCALON MINI MART
STREET_NUMBER
1097
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
ESCALON
Zip
95320
APN
22510001
CURRENT_STATUS
01
SITE_LOCATION
1097 YOSEMITE AVE
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231497_1097 YOSEMITE_2010-2014.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
487
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MSAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sjgov.org/ehd <br /> CONTINUATION FORM Page: 4 of 5 <br /> OFFICIAL INSPECTION REPORT Date: 01/09/14 <br /> Facility Address: 1097 Yosemite Ave, Escalon, CA Program: UST <br /> SUMMARY OF VIOLATIONS <br /> CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> 302 & 308. Jumper hoses, connecting the flexible product piping, were found inside all the STP sumps <br /> and inside the UDCs 1/2 through 5/6. As such, any potential release from the primary containment into <br /> the secondary containment in the 87-octane and 91-octane flexible piping does not flow into a collection <br /> sump. All secondary containment systems shall be sloped so that all releases will flow to a collection <br /> sump located at the low point of the underground piping. The technician onsite disconnected the jumper <br /> hoses located all STPs sumps and UDCs 1/2 and UDCs 5/6, however, he was unable to disconnect the <br /> hoses in UDC 3/4 due to a deeper jumper hose placement. Immediately contact a properly licensed, <br /> trained, and certified contractor to ensure that any releases in the 87 and 91 piping flows into the UDC <br /> 3/4 sump. <br /> 303. The 87-octane sump sensor was located approximately 3-inches up the sump saddle and not <br /> located to detect a leak at the earliest opportunity. Monitoring equipment shall be maintained to be able <br /> to detect a leak at the earliest possible opportunity. The technician onsite repositioned the sensor to <br /> detect any future leak at the earliest opportunity. CORRECTED. <br /> 305. The UDC 3/4 sensor failed to activate an audible and visual alarm when tested to ensure <br /> continuous monitoring of the tank system. All monitoring equipment shall be maintained to activate an <br /> audible and visual alarm or stop the flow of product at the dispenser when it detects a leak. The <br /> technician onsite cleaned the sensor, retested, and it passed. CORRECTED. <br /> 108 & 307. The most recent secondary containment test results (December 19-20, 2012) indicated a <br /> failure at UDC 3/4 and UDC 5/6. All secondary containment for the UST system must be tight. A permit <br /> was obtained from the EHD on March 15, 2013 (SR0066337) to repair the aforementioned components. <br /> According to an email communication from Franzen-Hill Corporation, dated April 17, 2013, a successful <br /> secondary containment testing was conducted for the UDC 5/6 on March 25, 2013. According to the <br /> aforementioned correspondence, additional repairs are still necessary for the UDC 1/2. Immediately <br /> have a properly licensed, trained, and certified contractor repair or replace the failed components under <br /> permit and inspection of the EHD. Furthermore, according to Franzen-Hill Corporation, a secondary <br /> containment testing was performed on March 25, 2013 and a test report has not been submitted to the <br /> EHD. A copy of the test report must be submitted within 30 days of the test. Immediately submit a copy <br /> of the test report to the EHD. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> EHD Inspector: Received By: Title: <br /> Elena Manzo (209) 953-7699 c!/� b�' � '� <br /> EHD 23-02-003 Rev 04/19/12 CONTINUATION FORM <br />
The URL can be used to link to this page
Your browser does not support the video tag.