My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2015-2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1097
>
2300 - Underground Storage Tank Program
>
PR0231497
>
COMPLIANCE INFO_2015-2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/11/2023 2:05:16 PM
Creation date
6/3/2020 9:50:17 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2015-2019
RECORD_ID
PR0231497
PE
2361
FACILITY_ID
FA0000279
FACILITY_NAME
ESCALON MINI MART
STREET_NUMBER
1097
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
ESCALON
Zip
95320
APN
22510001
CURRENT_STATUS
01
SITE_LOCATION
1097 YOSEMITE AVE
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231497_1097 YOSEMITE_2015-2019.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
349
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The following is an itemized list of underground storage tank violations that have not <br />been addressed for ESCALON MINI MART as of March 30, 2015. <br />Open violations from January 08, 2015 inspection <br />Violation #109 - Failed to test secondary containment. <br />The most recent secondary containment testing results from December 19-20, 2012, indicated a failure at UDC 3/4 <br />and UDC 5/6. All secondary containment for the UST system must be tight. A permit was obtained from the EHD on <br />March 15, 2013 (SR0066337) to repair the aforementioned components. According to an email communication from <br />Franzen -Hill Corporation, dated April 17, 2013, a successful secondary containment test was conducted for the UDC <br />5/6 on March 25, 2013. No testing notification was provided to the EHD for testing conducted on March 25, 2013 and <br />therefore its results were not accepted. Immediately have a properly licensed, trained, and certified contractor repair <br />replace the failed components in UDC 3/4 and UDC 5/6 under permit and inspection from the EHD. This is a repeat <br />violation, Class II. <br />Violation #110 - Failed to submit secondary containment test report within 30 days. <br />According to Franzen -Hill Corporation, a secondary containment testing was performed on March 25, 2013 and a tes <br />report was not submitted to the EHD. A copy of the test report must be submitted within 30 days of the test. <br />Immediately submit a copy of this test report to the EHD. This is a repeat violation, Class II. <br />Violation #301 - UST system is not operated to prevent unauthorized release, including spills and overfills. <br />The most recent secondary containment testing results from December 19-20, 2012 indicated a failure at UDC 3/4 a <br />UDC 5/6. All secondary containment for the UST system must be tight. A permit was obtained from the EHD on <br />March 15, 2013 (SR0066337) to repair the aforementioned components. According to an email communication from <br />Franzen -Hill Corporation, dated April 17, 2013, on March 25, 2013 a successful secondary containment test was <br />conducted for the under dispenser containment (UDC) 5/6 , however, some additional repairs are still necessary for t <br />failures in UDC 3/4. The underground storage tank system shall be operated to prevent unauthorized releases. <br />Immediately make all necessary repairs under permit and inspection from the EHD. This is a repeat violation, Class I <br />Violation #317 - Secondary containment not tight. <br />According to an email communication from Franzen -Hill Corporation, dated April 17, 2013, some additional repairs a <br />still necessary for the secondary containment testing failure in the UDC 3/4. All secondary containment for the UST <br />system must be tight. Immediately have a properly licensed, trained, and certified contractor repair or replace the <br />failed component under permit and inspection of the EHD. This is a repeat violation, Class II. <br />Open violations from January 09, 2014 inspection <br />Page 1 of 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.