My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2015-2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1097
>
2300 - Underground Storage Tank Program
>
PR0231497
>
COMPLIANCE INFO_2015-2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/11/2023 2:05:16 PM
Creation date
6/3/2020 9:50:17 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2015-2019
RECORD_ID
PR0231497
PE
2361
FACILITY_ID
FA0000279
FACILITY_NAME
ESCALON MINI MART
STREET_NUMBER
1097
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
ESCALON
Zip
95320
APN
22510001
CURRENT_STATUS
01
SITE_LOCATION
1097 YOSEMITE AVE
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231497_1097 YOSEMITE_2015-2019.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
349
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Facility Name: <br />ESCALON MINI MART <br />Item # <br />1111111111W San Joaquin County <br />Environmental Health Department mx&a <br />� N � <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd� <br />Facility Address: <br />1097 YOSEMITE A <br />Remarks <br />Z <br />Date: <br />January 08, 2015 <br />HSC 25404(e)(4) Failed to report program data electronically. <br />A submission to the California Electronic Reporting System (CERS) for the underground storage tank (UST) program <br />has not been made. Beginning January 1, 2014, all businesses are required to submit all new (or any changes to <br />existing) UST information, including: UST Monitoring Site Plan, UST Certification of Financial Responsibility, UST <br />Response Plan, UST Owner/Operator Written Agreement (if applicable), UST Letter from Chief Financial Officer, and <br />Owner Statement of Designated UST Operator Compliance online to the CERS at http://cers.calepa.ca.gov. Be sure <br />to include any other relevant activities and required fields. This is a repeat violation, Class II. CORRECTED. <br />This is a Class II violation. <br />301 HSC 25292.1 UST system is not operated to prevent unauthorized release, including spills and overfills. <br />The most recent secondary containment testing results from December 19-20, 2012 indicated a failure at UDC 3/4 and <br />UDC 5/6. All secondary containment for the UST system must be tight. A permit was obtained from the EHD on <br />March 15, 2013 (SR0066337) to repair the aforementioned components. According to an email communication from <br />Franzen -Hill Corporation, dated April 17, 2013, on March 25, 2013 a successful secondary containment test was <br />conducted for the under dispenser containment (UDC) 5/6 , however, some additional repairs are still necessary for the <br />failures in UDC 3/4. The underground storage tank system shall be operated to prevent unauthorized releases. <br />Immediately make all necessary repairs under permit and inspection from the EHD. This is a repeat violation, Class II. <br />This is a Class II violation. <br />309 CCR 2636(f)(1) Monitoring in the UDCs failed to activate an audible and visual alarm or stop the flow at the UDC. <br />The UDC 5/6 sensor failed to stop the flow of product at the dispenser when tested, the wire to this particular sensor <br />was disconnected/ sheared off. All monitoring equipment shall be maintained to activate an audible and visual alarm <br />or stop the flow of product at the dispenser when it detects a leak. The existing sensor was reconnected and retested <br />successfully during the inspection. This is a Class II violation. CORRECTED. <br />This is a minor violation. <br />310 CCR 2636(f)(1) Sensor in a turbine sump failed to activate an audible and visual alarm or stop the flow product. <br />The 87 -octane STP sensor failed to activate an audible and visual alarm when tested to ensure continuous monitoring <br />of the tank system. All monitoring equipment shall be maintained to activate an audible and visual alarm or stop the <br />flow of product at the dispenser when it detects a leak. The technician onsite cleaned the sensor and retested with <br />passing results. CORRECTED. <br />This is a minor violation. <br />Received by Inspector: Phone: Date: <br />(initial): ELENA MANZO, REHS 1 (209) 953-7699 01/08/2015 <br />Page 5 of 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.