Laserfiche WebLink
S A N 3J O A Q U I N Environmental Health Department <br /> _C 0 U N TY_._ <br /> Underground Storage Tank Program'Inspection Report <br /> � x <br /> Facility Name: Facility Address: Date: <br /> ESCALON MINI MART 1097 YOSEMITE AVE, ESCALON December 18, 2018 <br /> g SUMMARY:OF VI LATION <br /> f3 <br /> GLASS 1,:9 II nr'MINOR Nouce to Comply <br /> i t <br /> Item# Remarks <br /> 210 CCR 2716(f) DO monthly reports not maintained on site for 12 months or for 36 months(after October 1,2018). <br /> The July 2018 and November 2018 designated operator monthly inspection reports were not found on site. <br /> Designated operator monthly inspection reports for the previous twelve months or 36 month(after October 1 st, <br /> 2018)shall be retained on site.The operator was able to get a copy of the reports while the inspector was on site to <br /> correct this on site. <br /> This was corrected on site. <br /> This is a repeat violation, Class II. <br /> 306 CCR 2630(d)Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity. <br /> The 87 product, 91 produt, UDC 7/8 sump sensor were raised approximately 2-5 inches off the lowest point of the <br /> sump and not located to detect a leak at the earliest opportunity. <br /> The ULS sensor located in the 91 STP sump was raised and tied on a fiberglass pipe approximately 4-5 inches <br /> based on the service technician calculations. <br /> The ULS sensor located in the 87 STP sump was raised and tied on a fiberglass pipe approximately 3-4 inches <br /> based on the service technician calculations. <br /> The ULS sensor located in the UDC 7/8 was raised and tied with a zip tide approximately 2-3 inches. <br /> Monitoring equipment shall be maintained to be able to detect a leak at the earliest possible opportunity. The <br /> sensor was relocated to the lowest point of the sump by the service technician. Ensure that all monitoring <br /> equipment is maintained to detect a leak at the earliest opportunity. <br /> This is a repeat violation, Class II. <br /> 315 HSC 25291(e)Water in secondary containment not removed, analyzed, and properly disposed of(pre-Jul 2003). <br /> Liquid was observed in the 87 product, UDC 3/4,UDC 7/8 sump. If water could enter into the secondary <br /> containment by precipitation or infiltration, it must be removed and disposed of properly. The service technician <br /> removed liquid from the 87 product, UDC 3/4, UDC 7/8 sump_ Ensure that all sumps and annular spaces are <br /> maintained free of liquid. <br /> This is a repeat violation, Class II. <br /> FA0000279 PR0231497 SC001 12/18/2018 <br /> EHD 23-01 Rev.09/28/2018 Page 6 of 8 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />